{"id":4038,"date":"2026-10-12T09:35:37","date_gmt":"2026-10-12T09:35:37","guid":{"rendered":"https:\/\/firstfibertech.com\/?p=4038"},"modified":"2026-10-28T10:58:43","modified_gmt":"2026-10-28T10:58:43","slug":"retos-de-la-prueba-otdr-a-1650-nm-en-servicio-para-redes-pon-de-10-g-que-coexisten-con-redes-gpon-heredadas","status":"publish","type":"post","link":"https:\/\/firstfibertech.com\/es\/blog\/challenges-of-1650-nm-in-service-otdr-testing-for-co-existing-10g-pon-and-legacy-gpon-networks\/","title":{"rendered":"Retos de las pruebas OTDR en servicio a 1650 nm para redes 10G-PON y GPON heredadas coexistentes"},"content":{"rendered":"<h2 class=\"wp-block-heading\">Resumen<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">El diagn\u00f3stico de fibras en servicio es esencial para los operadores que est\u00e1n desplegando redes 10G-PON junto a los abonados GPON existentes. Las mediciones tradicionales con OTDR fuera de banda a 1625 nm suelen verse degradadas por el ruido Raman y la diafon\u00eda de los filtros cuando las fibras transportan se\u00f1ales activas de 1490 nm en sentido descendente, lo que produce trazas ruidosas y eventos reflectivos espurios. Este art\u00edculo examina las limitaciones f\u00edsicas de las longitudes de onda de sondeo de 1625 nm en redes PON de generaciones mixtas, analiza las compensaciones \u00f3pticas fundamentales que supone la adopci\u00f3n de 1650 nm como banda de prueba alternativa y resume las restricciones operativas pr\u00e1cticas observadas durante ensayos de campo a gran escala en redes en funcionamiento. El an\u00e1lisis ofrece orientaci\u00f3n para definir los requisitos de prueba para NG-PON2 y futuras implementaciones de acceso por fibra de m\u00faltiples longitudes de onda.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">1. Introducci\u00f3n<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">La infraestructura de acceso por fibra suele admitir m\u00faltiples est\u00e1ndares PON en una misma fibra f\u00edsica. Cuando los operadores implementan XGS-PON (10G-PON), los servicios GPON existentes deben permanecer activos, lo que significa que la fibra transporta simult\u00e1neamente se\u00f1ales GPON de 1490 nm en sentido descendente junto con los nuevos canales de longitud de onda de 10G-PON. Por lo tanto, la localizaci\u00f3n de fallos y la verificaci\u00f3n de enlaces deben basarse en longitudes de onda de prueba fuera de banda que no interrumpan el tr\u00e1fico real de los abonados.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La banda de 1625 nm se utiliza desde hace tiempo para el mantenimiento sobre el terreno de redes GPON. Sin embargo, cuando esta longitud de onda de la sonda comparte la fibra con tr\u00e1fico descendente de alta potencia a 1490 nm, surgen dos mecanismos de degradaci\u00f3n: la fuga residual de las longitudes de onda de servicio a trav\u00e9s de los puertos del filtro WDM y la dispersi\u00f3n Raman inducida por la se\u00f1al \u00f3ptica en banda. Ambos fen\u00f3menos generan artefactos de medici\u00f3n, como un ruido elevado en la traza y eventos fantasma, lo que reduce la fiabilidad a la hora de localizar empalmes, conectores y puertos de divisores pasivos.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Para lograr una mayor separaci\u00f3n espectral respecto a todas las bandas de se\u00f1al PON activas, algunos planificadores de redes han identificado los 1650 nm como una longitud de onda candidata para pruebas fuera de banda. A 1650 nm, se mantiene un aislamiento suficiente en la banda de guarda para el tr\u00e1fico de 1270 nm, 1490 nm y 1577 nm, mientras que la banda sigue siendo compatible con mediciones a trav\u00e9s de divisores de alta relaci\u00f3n de hasta 1:64. Aun as\u00ed, el cambio de la operaci\u00f3n de prueba a 1650 nm introduce penalizaciones \u00f3pticas intr\u00ednsecas que deben abordarse en el hardware de prueba probado en condiciones reales.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A pesar del amplio despliegue de redes GPON y 10G-PON que coexisten, las directrices oficiales del sector que especifican las longitudes de onda preferidas para las pruebas fuera de banda en entornos h\u00edbridos siguen siendo incompletas. La mayor\u00eda de las especificaciones de prueba de los operadores regionales siguen recurriendo por defecto a los procedimientos de 1625 nm dise\u00f1ados para instalaciones GPON de una sola generaci\u00f3n, sin tener en cuenta los umbrales de ruido Raman causados por los canales de bajada de alta potencia de 10G-PON. Esto da lugar a una calidad de medici\u00f3n sobre el terreno inconsistente en las modernas implementaciones de acceso por fibra \u00f3ptica.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"559\" src=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/10\/Figure-1-Wavelength-spectrum-overview-in-co-existing-PON-environments-1024x559.jpg\" alt=\"Figura 1: Resumen del espectro de longitudes de onda en entornos PON coexistentes.\" class=\"wp-image-4040\" srcset=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/10\/Figure-1-Wavelength-spectrum-overview-in-co-existing-PON-environments-1024x559.jpg 1024w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/10\/Figure-1-Wavelength-spectrum-overview-in-co-existing-PON-environments-300x164.jpg 300w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/10\/Figure-1-Wavelength-spectrum-overview-in-co-existing-PON-environments-768x419.jpg 768w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/10\/Figure-1-Wavelength-spectrum-overview-in-co-existing-PON-environments-1536x838.jpg 1536w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/10\/Figure-1-Wavelength-spectrum-overview-in-co-existing-PON-environments-2048x1117.jpg 2048w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/10\/Figure-1-Wavelength-spectrum-overview-in-co-existing-PON-environments-18x10.jpg 18w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption translation-block\"><strong>Figura 1: <\/strong>Resumen del espectro de longitudes de onda en entornos PON coexistentes. <em>La se\u00f1al de bajada de alta potencia de XGS-PON a 1577 nm induce una banda de ruido Raman (\u00e1rea sombreada) que degrada gravemente las mediciones OTDR a 1625 nm, lo que demuestra la necesidad de desplazar la longitud de onda de prueba fuera de banda a 1650 nm para lograr un aislamiento espectral adecuado.<\/em><\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">2. Compromisos \u00f3pticos fundamentales para la implementaci\u00f3n de un OTDR de campo a 1650 nm<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">La principal limitaci\u00f3n de las pruebas a 1625 nm en enlaces 10G-PON activos se debe a la dispersi\u00f3n Raman estimulada (SRS). La se\u00f1al de bajada de alta potencia de 1577 nm del XGS-PON act\u00faa como l\u00e1ser de bombeo, generando ruido de fotones Raman desplazado hacia abajo precisamente dentro de la ventana de prueba del OTDR de 1620-1630 nm. El ruido de fondo resultante aumenta de forma no lineal con la potencia de emisi\u00f3n y la longitud de la fibra, lo que produce artefactos reflectivos aleatorios que no pueden filtrarse \u00fanicamente mediante el promedio digital convencional.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">En comparaci\u00f3n con los 1625 nm, los 1650 nm presentan una menor eficiencia de retrodispersi\u00f3n de Rayleigh y una atenuaci\u00f3n intr\u00ednseca de la fibra ligeramente superior. Ambos efectos reducen el rango din\u00e1mico alcanzable, el principal indicador de rendimiento para probar redes de distribuci\u00f3n PON basadas en divisores y limitadas por la p\u00e9rdida. Hay tres consideraciones fundamentales de dise\u00f1o que determinan la viabilidad de la instrumentaci\u00f3n de campo:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Fuente l\u00e1ser estable de ancho de l\u00ednea estrecho: El transmisor debe proporcionar una potencia de sonda \u00fatil sin sobrepasar los l\u00edmites de seguridad ocular de la Clase 1. Se requiere estabilidad de la potencia de salida a lo largo de los ciclos de temperatura para mantener la repetibilidad de la traza en entornos no controlados de la red exterior.<\/li>\n\n\n\n<li>Front-end de receptor \u00f3ptico de bajo ruido: Se necesitan circuitos receptores con fotodiodos de avalancha y amplificaci\u00f3n multietapa para recuperar se\u00f1ales reflejadas d\u00e9biles tras la atenuaci\u00f3n provocada por los divisores PON en cascada. Es necesario controlar el umbral de ruido del receptor para preservar la resoluci\u00f3n espacial en el caso de eventos reflectantes muy pr\u00f3ximos entre s\u00ed.<\/li>\n\n\n\n<li>Procesamiento de se\u00f1ales digitales: los algoritmos de supresi\u00f3n de ruido y la l\u00f3gica de mitigaci\u00f3n de la zona muerta son fundamentales para las instalaciones en edificios de viviendas m\u00faltiples (MDU), en las que hay numerosos conectores y empalmes en un tramo corto de fibra.<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\">Cuando estas limitaciones se resuelven a nivel de hardware y firmware, una plataforma OTDR de 1650 nm puede ofrecer un rango din\u00e1mico superior a 37 dB y una zona muerta de eventos inferior a 1 m, lo que la hace adecuada para la localizaci\u00f3n de fallos en arquitecturas t\u00edpicas de distribuci\u00f3n 10G-PON.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"572\" src=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/10\/In-service-1625-nm-OTDR-trace-measured-on-an-active-10G-PON-link.jpg\" alt=\"Traza OTDR de 1625 nm en servicio, medida en un enlace 10G-PON activo.\" class=\"wp-image-4043\" srcset=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/10\/In-service-1625-nm-OTDR-trace-measured-on-an-active-10G-PON-link.jpg 1024w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/10\/In-service-1625-nm-OTDR-trace-measured-on-an-active-10G-PON-link-300x168.jpg 300w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/10\/In-service-1625-nm-OTDR-trace-measured-on-an-active-10G-PON-link-768x429.jpg 768w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/10\/In-service-1625-nm-OTDR-trace-measured-on-an-active-10G-PON-link-18x10.jpg 18w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\"><strong>Figura 2:<\/strong> Traza OTDR de 1625 nm obtenida en servicio en un enlace 10G-PON activo. La medici\u00f3n se ve gravemente afectada por la dispersi\u00f3n Raman estimulada inducida por la se\u00f1al de alta potencia de 1577 nm en sentido descendente, lo que provoca un aumento significativo del ruido de fondo y la aparici\u00f3n de eventos fantasma espurios.<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"572\" src=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/10\/In-service-1650-nm-OTDR-trace-measured-on-the-same-active-10G-PON-link.jpg\" alt=\"Traza OTDR de 1650 nm en servicio, medida en el mismo enlace activo 10G-PON\" class=\"wp-image-4044\" srcset=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/10\/In-service-1650-nm-OTDR-trace-measured-on-the-same-active-10G-PON-link.jpg 1024w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/10\/In-service-1650-nm-OTDR-trace-measured-on-the-same-active-10G-PON-link-300x168.jpg 300w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/10\/In-service-1650-nm-OTDR-trace-measured-on-the-same-active-10G-PON-link-768x429.jpg 768w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/10\/In-service-1650-nm-OTDR-trace-measured-on-the-same-active-10G-PON-link-18x10.jpg 18w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\"><strong>Figura 3:<\/strong> Traza OTDR a 1650 nm obtenida en servicio en el mismo enlace activo 10G-PON. Al proporcionar un aislamiento espectral adecuado respecto a la banda de ruido Raman, la longitud de onda de la sonda de 1650 nm mantiene una l\u00ednea de base limpia, lo que permite localizar con precisi\u00f3n los componentes \u00f3pticos pasivos y las posibles aver\u00edas.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">3. Limitaciones operativas observadas durante las pruebas en red real<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">El rendimiento en banco de pruebas por s\u00ed solo no garantiza la idoneidad para los flujos de trabajo sobre el terreno. Las pruebas realizadas en redes PON en servicio urbanas, suburbanas y en edificios residenciales (MDU) dos limitaciones pr\u00e1cticas comunes a los instrumentos de prueba de instalaciones exteriores, independientemente de la arquitectura \u00f3ptica subyacente.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">En primer lugar, las pantallas convencionales presentan un contraste deficiente bajo la luz solar directa. Para los t\u00e9cnicos que trabajan en armarios de calle y puntos de empalme a\u00e9reos, la menor legibilidad de los trazos ralentiza el diagn\u00f3stico de aver\u00edas. Cualquier instrumento de campo destinado a este uso debe dar prioridad a las caracter\u00edsticas de legibilidad de la pantalla bajo la luz solar.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">En segundo lugar, los programas de aceptaci\u00f3n y mantenimiento de redes PON de alta densidad exigen que los t\u00e9cnicos eval\u00faen un gran volumen de enlaces de fibra por turno. La repetida colocaci\u00f3n manual del cursor para extraer par\u00e1metros b\u00e1sicos, como la longitud de la fibra y la p\u00e9rdida total, genera una carga de trabajo innecesaria. La detecci\u00f3n automatizada de eventos y la generaci\u00f3n de informes de par\u00e1metros pueden agilizar estos flujos de trabajo de pruebas de alto rendimiento.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">En el entorno de pruebas, las mediciones a 1650 nm se llevaron a cabo sin interrumpir los servicios PON activos que compart\u00edan la misma ubicaci\u00f3n, y la arquitectura de pruebas era compatible con las interfaces centralizadas de monitorizaci\u00f3n automatizada de la fibra.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">4. Discusi\u00f3n y perspectivas<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A medida que se ampl\u00eden los despliegues de NG-PON2 y 25G-PON, la coexistencia de m\u00faltiples longitudes de onda de servicio en una fibra compartida se convertir\u00e1 en una pr\u00e1ctica habitual. La selecci\u00f3n de las bandas de prueba fuera de banda debe evaluarse teniendo en cuenta el conjunto completo de canales activos para preservar unas bandas de protecci\u00f3n espectrales adecuadas.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La banda de 1650 nm ofrece claras ventajas de aislamiento para las redes PON mixtas; sin embargo, no es un sustituto universal de la de 1625 nm. Una mayor atenuaci\u00f3n de la fibra limita el alcance m\u00e1ximo en tramos de alimentaci\u00f3n largos, y la disponibilidad de componentes, junto con el coste del sistema, siguen siendo factores limitantes en la pr\u00e1ctica para algunos operadores. Los dise\u00f1adores de instrumentos deben encontrar un equilibrio entre el rendimiento \u00f3ptico bruto y los requisitos de usabilidad sobre el terreno, incluyendo la visibilidad de la pantalla, el an\u00e1lisis automatizado y la compatibilidad con las plataformas de monitorizaci\u00f3n.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">En condiciones pr\u00e1cticas de campo, las trazas de OTDR a 1625 nm en fibras 10G-PON activas suelen presentar un aumento del ruido de fondo de entre 6 dB y 12 dB en comparaci\u00f3n con las pruebas en fibra oscura. Este margen de ruido es suficiente para ocultar empalmes con bajas p\u00e9rdidas y reflexiones d\u00e9biles en los conectores, aspectos que resultan fundamentales para el mantenimiento preventivo. Por el contrario, el desplazamiento a 1650 nm proporciona aproximadamente 25 nm de aislamiento espectral respecto a la banda de ruido Raman, lo que elimina la mayor parte de la degradaci\u00f3n de las mediciones en servicio.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Los resultados operativos de las pruebas en condiciones reales de 10G-PON demuestran que la selecci\u00f3n de la longitud de onda es solo una parte de las especificaciones de prueba. Su utilidad en el mundo real depende en igual medida de que se tengan en cuenta las limitaciones del flujo de trabajo sobre el terreno, que a menudo no se recogen en la caracterizaci\u00f3n de los componentes realizada en laboratorio. Estas consideraciones pueden servir de base para definir los requisitos de hardware de los sistemas de prueba de redes de acceso de pr\u00f3xima generaci\u00f3n.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A medida que los sistemas NG-PON2 y 25G-PON comiencen su despliegue comercial, la coexistencia de longitudes de onda superpuestas se volver\u00e1 a\u00fan m\u00e1s compleja. Los criterios de selecci\u00f3n de longitudes de onda de prueba que se exponen en este art\u00edculo pueden servir de base para la actualizaci\u00f3n de los procedimientos operativos est\u00e1ndar de los operadores y contribuir a la creaci\u00f3n de marcos de validaci\u00f3n sobre el terreno m\u00e1s s\u00f3lidos para las redes de acceso de fibra multibanda de pr\u00f3xima generaci\u00f3n.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">5. Modelos de OTDR de 1650 nm de FirstFiber Technologies<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Modelo<\/th><th>Longitud de onda<\/th><th>Rango din\u00e1mico<\/th><\/tr><\/thead><tbody><tr><td><a href=\"https:\/\/firstfibertech.com\/es\/producto\/8000-max-otdr\/\" data-type=\"ff_products\" data-id=\"469\">8000MAX-T3<\/a><\/td><td>1310\/1550\/1650 nm<\/td><td>35\/33\/32 dB<\/td><\/tr><tr><td><a href=\"https:\/\/firstfibertech.com\/es\/producto\/8000-max-otdr\/\" data-type=\"ff_products\" data-id=\"469\">8000MAX-10G2<\/a><\/td><td>1310\/1550\/1270\/1577\/1650nm<\/td><td>37\/35\/35\/35\/35 dB<\/td><\/tr><tr><td><a href=\"https:\/\/firstfibertech.com\/es\/producto\/980exp-12-en-1-otdr\/\" data-type=\"ff_products\" data-id=\"369\">980EXP-B32<\/a><\/td><td>1650 nm<\/td><td>32 dB<\/td><\/tr><tr><td><a href=\"https:\/\/firstfibertech.com\/es\/producto\/ff-990pro-otdr\/\" data-type=\"ff_products\" data-id=\"516\">FF-990PRO-PS2<\/a><\/td><td>1650 nm<\/td><td>38 dB<\/td><\/tr><tr><td><a href=\"https:\/\/firstfibertech.com\/es\/producto\/ff-990pro-otdr\/\" data-type=\"ff_products\" data-id=\"516\">FF-990PRO-PT4<\/a><\/td><td>1310\/1550\/1650 nm<\/td><td>38\/36\/36 dB<\/td><\/tr><tr><td><a href=\"https:\/\/firstfibertech.com\/es\/producto\/980rtc-mini-otdr-practico\/\" data-type=\"ff_products\" data-id=\"480\">980RTC-B26<\/a><\/td><td>1650 nm<\/td><td>26 dB<\/td><\/tr><tr><td><a href=\"https:\/\/firstfibertech.com\/es\/producto\/980rtc-mini-otdr-practico\/\" data-type=\"ff_products\" data-id=\"480\">980RTC-T3<\/a><\/td><td>1310\/1550\/1650 nm<\/td><td>24\/22\/22 dB<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Comprobar <a href=\"https:\/\/firstfibertech.com\/es\/productos\/prueba-y-medicion\/otdrs\/\" data-type=\"ff_product_cat\" data-id=\"6\">todos los modelos de OTDR<\/a>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>Resumen: El diagn\u00f3stico de fibras en servicio es esencial para los operadores que est\u00e1n desplegando redes 10G-PON junto a los abonados GPON existentes. Las mediciones tradicionales con OTDR fuera de banda a 1625 nm suelen verse degradadas por el ruido Raman y la diafon\u00eda de los filtros cuando las fibras transportan se\u00f1ales activas de 1490 nm en sentido descendente, lo que produce trazas ruidosas y eventos reflectivos espurios. Este art\u00edculo examina las limitaciones f\u00edsicas de las longitudes de onda de sondeo de 1625 nm en redes de generaciones mixtas\u2026 <a title=\"Retos de las pruebas OTDR en servicio a 1650 nm para redes 10G-PON y GPON heredadas coexistentes\" class=\"read-more\" href=\"https:\/\/firstfibertech.com\/es\/blog\/challenges-of-1650-nm-in-service-otdr-testing-for-co-existing-10g-pon-and-legacy-gpon-networks\/\" aria-label=\"Leer m\u00e1s sobre Challenges of 1650\u202fnm in\u2011service OTDR testing for co\u2011existing 10G\u2011PON and legacy GPON networks\">Leer m\u00e1s<\/a><\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[98],"tags":[],"class_list":["post-4038","post","type-post","status-publish","format-standard","hentry","category-otdr-wiki"],"_links":{"self":[{"href":"https:\/\/firstfibertech.com\/es\/wp-json\/wp\/v2\/posts\/4038","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/firstfibertech.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/firstfibertech.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/firstfibertech.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/firstfibertech.com\/es\/wp-json\/wp\/v2\/comments?post=4038"}],"version-history":[{"count":3,"href":"https:\/\/firstfibertech.com\/es\/wp-json\/wp\/v2\/posts\/4038\/revisions"}],"predecessor-version":[{"id":4046,"href":"https:\/\/firstfibertech.com\/es\/wp-json\/wp\/v2\/posts\/4038\/revisions\/4046"}],"wp:attachment":[{"href":"https:\/\/firstfibertech.com\/es\/wp-json\/wp\/v2\/media?parent=4038"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/firstfibertech.com\/es\/wp-json\/wp\/v2\/categories?post=4038"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/firstfibertech.com\/es\/wp-json\/wp\/v2\/tags?post=4038"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}