{"id":1456,"date":"2026-08-06T05:15:03","date_gmt":"2026-08-06T05:15:03","guid":{"rendered":"https:\/\/firstfibertech.com\/?post_type=ff_products&#038;p=1456"},"modified":"2026-09-07T03:09:51","modified_gmt":"2026-09-07T03:09:51","slug":"esc25d-apc-sc-connecteur-rapide-apc","status":"publish","type":"ff_products","link":"https:\/\/firstfibertech.com\/fr\/product\/esc25d-apc-sc-apc-fast-connector\/","title":{"rendered":"Connecteur rapide ESC25D-APC SC\/APC\u00a0"},"content":{"rendered":"<h2 class=\"wp-block-heading\">Description<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">ESC25D-APC SC\/APC : connecteur rapide pour c\u00e2bles de d\u00e9rivation de 2 \u00d7 3 mm et 1,6 \u00d7 2 mm ; connecteur d'assemblage sur site pour fibre optique FTTH&nbsp;<br><br><strong>Caract\u00e9ristiques<\/strong><br>1. Projet FTTH exploitable<br>2. Pour une installation rapide sur site<br>3. Perte d'insertion typique : 0,3 dB<br>4. Pour les c\u00e2bles papillon FTTH de 2,0 \u00d7 3,0 mm et 1,6 \u00d7 2,0 mm<br>5. Installation en moins d'une minute<br>6. Performances optiques fiables et exceptionnelles<br>7. L'essai de traction sur c\u00e2ble est conforme \u00e0 la norme Telcordia GR-326-COR<br>8. Norme YD\/T 2341.1-2011<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td>Valable pour&nbsp;<\/td><td>C\u00e2ble de d\u00e9rivation 2,0 \u00d7 3,0 mm \/ C\u00e2ble de d\u00e9rivation 1,6 \u00d7 2,0 mm<\/td><\/tr><tr><td>Diam\u00e8tre du c\u0153ur et de la gaine de la fibre optique<\/td><td>9\/125 \u00b5m SM (G652D\/G657A\/G657B)<\/td><\/tr><tr><td>Diam\u00e8tre du rev\u00eatement de la fibre<\/td><td>250 \u00b5m<\/td><\/tr><tr><td>Dur\u00e9e de l'intervention<\/td><td>Moins d'une minute<\/td><\/tr><tr><td>Perte d'insertion typique<\/td><td>0,3 dB<\/td><\/tr><tr><td>Perte d'insertion maximale<\/td><td>0,5 dB<\/td><\/tr><tr><td>R\u00e9sistance \u00e0 la traction<\/td><td>&gt;30 N<\/td><\/tr><tr><td>Longueur du connecteur<\/td><td>52 mm<\/td><\/tr><tr><td>Perte de retour<\/td><td>&gt;55 dB<\/td><\/tr><tr><td>R\u00e9p\u00e9ter l'assemblage<\/td><td>&gt;10 fois<\/td><\/tr><tr><td>Temp\u00e9rature de fonctionnement<\/td><td>de -40 \u00e0 +85 degr\u00e9s Celsius<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Comment l'adapter \u00e0 la fois \u00e0 un c\u00e2ble de 2,0 \u00d7 3,0 mm et \u00e0 un c\u00e2ble de 1,6 \u00d7 2,0 mm<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"540\" height=\"308\" src=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/esc25d-apc-drop-cable-installation.webp\" alt=\"Installation d&#039;un c\u00e2ble de d\u00e9rivation \u00e0 connecteur rapide ESC25D-APC\" class=\"wp-image-1460\" srcset=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/esc25d-apc-drop-cable-installation.webp 540w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/esc25d-apc-drop-cable-installation-300x171.webp 300w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/esc25d-apc-drop-cable-installation-18x10.webp 18w\" sizes=\"auto, (max-width: 540px) 100vw, 540px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"750\" height=\"417\" src=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/esc25d-apc-sc-apc-ftth-connector.webp\" alt=\"Connecteur rapide ESC25D-APC SC\/APC FTTH \u00e0 assembler sur site\" class=\"wp-image-1461\" srcset=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/esc25d-apc-sc-apc-ftth-connector.webp 750w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/esc25d-apc-sc-apc-ftth-connector-300x167.webp 300w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/esc25d-apc-sc-apc-ftth-connector-18x10.webp 18w\" sizes=\"auto, (max-width: 750px) 100vw, 750px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"750\" height=\"814\" src=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/esc25d-apc-field-assembly-connector-manual.webp\" alt=\"Manuel du connecteur optique ESC25D-APC \u00e0 assembler sur site\" class=\"wp-image-1462\" srcset=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/esc25d-apc-field-assembly-connector-manual.webp 750w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/esc25d-apc-field-assembly-connector-manual-276x300.webp 276w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/esc25d-apc-field-assembly-connector-manual-11x12.webp 11w\" sizes=\"auto, (max-width: 750px) 100vw, 750px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"750\" height=\"750\" src=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/esc25d-apc-cable-preparation.webp\" alt=\"Pr\u00e9paration du c\u00e2ble \u00e0 connecteur rapide ESC25D-APC\" class=\"wp-image-1463\" srcset=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/esc25d-apc-cable-preparation.webp 750w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/esc25d-apc-cable-preparation-300x300.webp 300w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/esc25d-apc-cable-preparation-150x150.webp 150w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/esc25d-apc-cable-preparation-12x12.webp 12w\" sizes=\"auto, (max-width: 750px) 100vw, 750px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"750\" height=\"750\" src=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/esc25d-apc-connector-installation-steps.webp\" alt=\"\u00c9tapes d&#039;installation du connecteur rapide ESC25D-APC SC\/APC\" class=\"wp-image-1464\" srcset=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/esc25d-apc-connector-installation-steps.webp 750w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/esc25d-apc-connector-installation-steps-300x300.webp 300w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/esc25d-apc-connector-installation-steps-150x150.webp 150w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/esc25d-apc-connector-installation-steps-12x12.webp 12w\" sizes=\"auto, (max-width: 750px) 100vw, 750px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"750\" height=\"820\" src=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/esc25d-apc-fast-connector-assembly-SFZJ.webp\" alt=\"\u00c9tapes de montage du connecteur rapide ESC25D-APC SC\/APC\" class=\"wp-image-1465\" srcset=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/esc25d-apc-fast-connector-assembly-SFZJ.webp 750w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/esc25d-apc-fast-connector-assembly-SFZJ-274x300.webp 274w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/esc25d-apc-fast-connector-assembly-SFZJ-11x12.webp 11w\" sizes=\"auto, (max-width: 750px) 100vw, 750px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"750\" height=\"820\" src=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/esc25d-apc-connector-assembly-Dxgb.webp\" alt=\"Guide de montage du connecteur rapide ESC25D-APC SC\/APC\" class=\"wp-image-1466\" srcset=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/esc25d-apc-connector-assembly-Dxgb.webp 750w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/esc25d-apc-connector-assembly-Dxgb-274x300.webp 274w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/esc25d-apc-connector-assembly-Dxgb-11x12.webp 11w\" sizes=\"auto, (max-width: 750px) 100vw, 750px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"750\" height=\"720\" src=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/esc25d-apc-cleaving-procedure.webp\" alt=\"Proc\u00e9dure de coupe de fibre optique pour connecteur rapide ESC25D-APC\" class=\"wp-image-1467\" srcset=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/esc25d-apc-cleaving-procedure.webp 750w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/esc25d-apc-cleaving-procedure-300x288.webp 300w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/esc25d-apc-cleaving-procedure-13x12.webp 13w\" sizes=\"auto, (max-width: 750px) 100vw, 750px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"750\" height=\"720\" src=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/esc25d-fiber-cleaving-guide.webp\" alt=\"Guide de longueur de coupe de fibre pour l&#039;ESC25D-APC\" class=\"wp-image-1468\" srcset=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/esc25d-fiber-cleaving-guide.webp 750w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/esc25d-fiber-cleaving-guide-300x288.webp 300w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/esc25d-fiber-cleaving-guide-13x12.webp 13w\" sizes=\"auto, (max-width: 750px) 100vw, 750px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"750\" height=\"677\" src=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/esc25d-apc-fast-connector-assembly.webp\" alt=\"\u00c9tapes de montage du connecteur \u00e0 fibre optique ESC25D-APC SC\/APC\" class=\"wp-image-1469\" srcset=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/esc25d-apc-fast-connector-assembly.webp 750w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/esc25d-apc-fast-connector-assembly-300x271.webp 300w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/esc25d-apc-fast-connector-assembly-13x12.webp 13w\" sizes=\"auto, (max-width: 750px) 100vw, 750px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"750\" height=\"677\" src=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/esc25d-apc-connector-assembly-steps.webp\" alt=\"\u00c9tapes d&#039;installation du connecteur rapide ESC25D-APC SC\/APC\" class=\"wp-image-1470\" srcset=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/esc25d-apc-connector-assembly-steps.webp 750w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/esc25d-apc-connector-assembly-steps-300x271.webp 300w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/esc25d-apc-connector-assembly-steps-13x12.webp 13w\" sizes=\"auto, (max-width: 750px) 100vw, 750px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"640\" height=\"1024\" src=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/esc25d-apc-repeat-assembly-wpYh-640x1024.webp\" alt=\"Guide de r\u00e9assemblage des connecteurs rapides ESC25D-APC SC\/APC\" class=\"wp-image-1471\" srcset=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/esc25d-apc-repeat-assembly-wpYh-640x1024.webp 640w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/esc25d-apc-repeat-assembly-wpYh-188x300.webp 188w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/esc25d-apc-repeat-assembly-wpYh-8x12.webp 8w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/esc25d-apc-repeat-assembly-wpYh.webp 750w\" sizes=\"auto, (max-width: 640px) 100vw, 640px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"640\" height=\"1024\" src=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/esc25d-apc-repeat-assembly-y7ZV-640x1024.webp\" alt=\"ESC25D-APC : sous-ensemble de connecteurs rapides SC\/APC\" class=\"wp-image-1472\" srcset=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/esc25d-apc-repeat-assembly-y7ZV-640x1024.webp 640w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/esc25d-apc-repeat-assembly-y7ZV-188x300.webp 188w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/esc25d-apc-repeat-assembly-y7ZV-8x12.webp 8w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/esc25d-apc-repeat-assembly-y7ZV.webp 750w\" sizes=\"auto, (max-width: 640px) 100vw, 640px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"640\" height=\"1024\" src=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/esc25d-apc-repeat-assembly-640x10.webp\" alt=\"ESC25D-APC : sous-ensemble de connecteurs rapides SC\/APC\" class=\"wp-image-1473\" srcset=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/esc25d-apc-repeat-assembly-640x10.webp 640w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/esc25d-apc-repeat-assembly-188x300.webp 188w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/esc25d-apc-repeat-assembly-8x12.webp 8w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/esc25d-apc-repeat-assembly.webp 750w\" sizes=\"auto, (max-width: 640px) 100vw, 640px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"690\" src=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/esc25d-apc-connector-assembly.webp\" alt=\"Guide d&#039;installation du connecteur rapide ESC25D-APC SC\/APC\" class=\"wp-image-1474\" srcset=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/esc25d-apc-connector-assembly.webp 1000w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/esc25d-apc-connector-assembly-300x207.webp 300w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/esc25d-apc-connector-assembly-768x530.webp 768w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/esc25d-apc-connector-assembly-18x12.webp 18w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">FAQ<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q1 : Quelles sections de c\u00e2ble sont compatibles avec le connecteur rapide ESC25D-UPC ?<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>R :<\/strong> Ce connecteur est compatible avec les c\u00e2bles de d\u00e9rivation \u00ab papillon \u00bb FTTH de 2,0 \u00d7 3,0 mm et de 1,6 \u00d7 2,0 mm.<sup><\/sup>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q2 : Quelles sont les principales caract\u00e9ristiques optiques de ce connecteur ?<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>R :<\/strong> Il offre une perte d'insertion typique de 0,3 dB (0,5 dB au maximum) et une perte de retour sup\u00e9rieure \u00e0 50 dB.<sup><\/sup>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q3 : Combien de temps dure le montage sur site, et le connecteur peut-il \u00eatre r\u00e9utilis\u00e9 ?<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>R :<\/strong> L'installation prend moins d'une minute, et le connecteur peut \u00eatre remont\u00e9 plus de 10 fois.<sup><\/sup>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q4 : Quels types de fibres et quelles normes industrielles l'ESC25D-UPC prend-il en charge ?<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>R :<\/strong> Il prend en charge les fibres monomodes de 9\/125 \u00b5m (G652D, G657A, G657B) d'un diam\u00e8tre de gaine de 250 \u00b5m et est conforme aux normes Telcordia GR-326-COR et YD\/T 2341.1-2011<sup><\/sup>.<\/p>","protected":false},"excerpt":{"rendered":"<p>Description : Connecteur rapide ESC25D-APC SC\/APC pour c\u00e2bles de d\u00e9rivation de 2 \u00d7 3 mm et 1,6 \u00d7 2 mm \u2013 Connecteur d'assemblage sur site pour fibre optique FTTH  Caract\u00e9ristiques : 1. Compatible avec les projets FTTH ; 2. Pour une installation rapide sur site ; 3. Perte d'insertion typique : 0,3 dB ; 4. Convient aux c\u00e2bles papillon FTTH de 2,0 \u00d7 3,0 mm et 1,6 \u00d7 2,0 mm5. Installation en moins d\u2019une minute6. Performances optiques fiables et sup\u00e9rieures7. Essai de traction du c\u00e2ble conforme \u00e0 la norme Telcordia GR-326-COR8. \u2026 <a title=\"Connecteur rapide ESC25D-APC SC\/APC\u00a0\" class=\"read-more\" href=\"https:\/\/firstfibertech.com\/fr\/product\/esc25d-apc-sc-apc-fast-connector\/\" aria-label=\"En savoir plus sur ESC25D-APC SC\/APC Fast Connector\u00a0\">Lire la suite<\/a><\/p>","protected":false},"featured_media":2964,"template":"","ff_product_cat":[58,26,54],"class_list":["post-1456","ff_products","type-ff_products","status-publish","has-post-thumbnail","hentry","ff_product_cat-fast-field-assembly","ff_product_cat-fiber-cabling","ff_product_cat-fiber-connector-and-adapter"],"_links":{"self":[{"href":"https:\/\/firstfibertech.com\/fr\/wp-json\/wp\/v2\/ff_products\/1456","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/firstfibertech.com\/fr\/wp-json\/wp\/v2\/ff_products"}],"about":[{"href":"https:\/\/firstfibertech.com\/fr\/wp-json\/wp\/v2\/types\/ff_products"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/firstfibertech.com\/fr\/wp-json\/wp\/v2\/media\/2964"}],"wp:attachment":[{"href":"https:\/\/firstfibertech.com\/fr\/wp-json\/wp\/v2\/media?parent=1456"}],"wp:term":[{"taxonomy":"ff_product_cat","embeddable":true,"href":"https:\/\/firstfibertech.com\/fr\/wp-json\/wp\/v2\/ff_product_cat?post=1456"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}