{"id":2493,"date":"2026-08-12T05:52:49","date_gmt":"2026-08-12T05:52:49","guid":{"rendered":"https:\/\/firstfibertech.com\/?post_type=ff_products&#038;p=2493"},"modified":"2026-09-01T08:10:54","modified_gmt":"2026-09-01T08:10:54","slug":"gyfty","status":"publish","type":"ff_products","link":"https:\/\/firstfibertech.com\/fr\/product\/gyfty\/","title":{"rendered":"C\u00e2ble \u00e0 fibre optique d'ext\u00e9rieur GYFTY"},"content":{"rendered":"<h2 class=\"wp-block-heading\">Description<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Les fibres, d\u2019un diam\u00e8tre de 200\/250 \u03bcm, sont dispos\u00e9es dans un tube l\u00e2che en plastique \u00e0 module \u00e9lev\u00e9. Les tubes sont remplis d\u2019un compos\u00e9 de remplissage r\u00e9sistant \u00e0 l\u2019eau. Un composite renforc\u00e9 de fibres (FRP) est plac\u00e9 au centre de l\u2019\u00e2me en tant qu\u2019\u00e9l\u00e9ment de renforcement non m\u00e9tallique. Les tubes (et les mat\u00e9riaux de remplissage) sont tress\u00e9s autour de cet \u00e9l\u00e9ment de renforcement pour former une \u00e2me compacte et circulaire. Une fois l\u2019\u00e2me du c\u00e2ble remplie de compos\u00e9 de remplissage afin de la prot\u00e9ger contre les infiltrations d\u2019eau, le c\u00e2ble est recouvert d\u2019une gaine en poly\u00e9thyl\u00e8ne.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Caract\u00e9ristiques du produit<\/strong><br><br>\u00b7Bonnes performances m\u00e9caniques et thermiques<br>\u00b7Tube l\u00e2che \u00e0 haute r\u00e9sistance, r\u00e9sistant \u00e0 l'hydrolyse&nbsp;<br>Un compos\u00e9 de remplissage sp\u00e9cial pour tubes assure une protection essentielle des fibres<br>\u00b7Bonne capacit\u00e9 \u00e0 s'\u00e9craser et texture moelleuse<br>\u00b7Adoptez les mesures ci-dessous pour garantir l'\u00e9tanch\u00e9it\u00e9 :<br>\u00b7un seul \u00e9l\u00e9ment de renfort central non m\u00e9tallique<br>Un compos\u00e9 de remplissage sp\u00e9cial pour tubes assure une protection essentielle des fibres<br>\u00b7enti\u00e8rement rembourr\u00e9 de fibres<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Norme relative au produit&nbsp;<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u00b7 Le c\u00e2ble GYFTY est conforme \u00e0 la norme YD\/T 901-2009 ainsi qu\u2019\u00e0 la norme CEI 60794-1.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Caract\u00e9ristiques optiques<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td colspan=\"2\">&nbsp;<\/td><td>G.652<\/td><td>G.655<\/td><td>50\/125 \u03bcm<\/td><td>62,5\/125 \u03bcm<\/td><\/tr><tr><td rowspan=\"4\">Att\u00e9nuation&nbsp;<br>&nbsp; &nbsp; &nbsp;(+20\u2103)<\/td><td>\u00e0 850 nm<\/td><td>&nbsp;<\/td><td>&nbsp;<\/td><td>\u22643,0 dB\/km<\/td><td>\u22643,0 dB\/km<\/td><\/tr><tr><td>\u00e0 1300 nm<\/td><td>&nbsp;<\/td><td>&nbsp;<\/td><td>\u22641,0 dB\/km<\/td><td>\u22641,0 dB\/km<\/td><\/tr><tr><td>\u00e0 1310 nm<\/td><td>\u22640,36 dB\/km<\/td><td>\u22640,36 dB\/km<\/td><td>&nbsp;<\/td><td>&nbsp;<\/td><\/tr><tr><td>\u00e0 1550 nm<\/td><td>\u22640,22 dB\/km<\/td><td>\u22640,23 dB\/km<\/td><td>&nbsp;<\/td><td>&nbsp;<\/td><\/tr><tr><td rowspan=\"2\">Bande passante (classe A)&nbsp; &nbsp; &nbsp;&nbsp;<\/td><td>@850<\/td><td>&nbsp;<\/td><td>&nbsp;<\/td><td>\u2265500 MHz\u00b7km<\/td><td>\u2265 200 MHz\u00b7km<\/td><\/tr><tr><td>@1300<\/td><td>&nbsp;<\/td><td>&nbsp;<\/td><td>\u22651000 MHz\u00b7km<\/td><td>\u2265600 MHz\u00b7km<\/td><\/tr><tr><td>Ouverture num\u00e9rique<\/td><td>&nbsp;<\/td><td>&nbsp;<\/td><td>&nbsp;<\/td><td>0,200 \u00b1 0,015 NA<\/td><td>0,275\u00b10,015NA<\/td><\/tr><tr><td>Longueur d'onde de coupure du c\u00e2ble \u03bbcc<\/td><td>&nbsp;<\/td><td>\u22641260 nm<\/td><td>\u22641480 nm<\/td><td>&nbsp;<\/td><td><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Param\u00e8tres techniques<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td>Type de c\u00e2ble<\/td><td>Nombre de fibres<\/td><td>nombre de tubes libres<\/td><td>nombre de remplissage<\/td><td>Diam\u00e8tre du c\u00e2ble<br>&nbsp; &nbsp;Mm<\/td><td>Poids du c\u00e2ble&nbsp;<br>&nbsp; Kg\/km<\/td><td>R\u00e9sistance \u00e0 la traction&nbsp;&nbsp;<br>\u00e0 long\/court terme<br>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp;N<\/td><td>R\u00e9sistance \u00e0 l&#039;\u00e9crasement<br>Long terme \/ court terme   N\/100 mm<\/td><td>Pliage&nbsp;<br>Rayon<br>mm statique\/dynamique<\/td><\/tr><tr><td>GYFTY-2 \u00e0 6<\/td><td>2\uff5e6<\/td><td>1<\/td><td>4<\/td><td>9.0<\/td><td>88<\/td><td>800\/1500<\/td><td>500\/1000<\/td><td>&nbsp; 15D\/30D<\/td><\/tr><tr><td>GYFTY-8 \u00e0 12<\/td><td>8\uff5e12<\/td><td>2<\/td><td>3<\/td><td>9.0<\/td><td>88<\/td><td>800\/1500<\/td><td>500\/1000<\/td><td>15D\/30D<\/td><\/tr><tr><td>GYFTY-14 \u00e0 18<\/td><td>14\uff5e18<\/td><td>3<\/td><td>2<\/td><td>9.0<\/td><td>88<\/td><td>800\/1500<\/td><td>500\/1000<\/td><td>15D\/30D<\/td><\/tr><tr><td>GYFTY-20 \u00e0 24<\/td><td>20\uff5e24<\/td><td>4<\/td><td>1<\/td><td>9.0<\/td><td>88<\/td><td>800\/1500<\/td><td>500\/1000<\/td><td>15D\/30D<\/td><\/tr><tr><td>GYFTY-26 \u00e0 30<\/td><td>26\uff5e30<\/td><td>5<\/td><td>0<\/td><td>9.0<\/td><td>88<\/td><td>800\/1500<\/td><td>500\/1000<\/td><td>15D\/30D<\/td><\/tr><tr><td>GYFTY-32 \u00e0 36<\/td><td>32\uff5e36<\/td><td>5<\/td><td>0<\/td><td>9.0<\/td><td>88<\/td><td>800\/1500<\/td><td>500\/1000<\/td><td>15D\/30D<\/td><\/tr><tr><td>GYFTY-38 \u00e0 48<\/td><td>38\uff5e48<\/td><td>5<\/td><td>0<\/td><td>9.0<\/td><td>88<\/td><td>800\/1500<\/td><td>500\/1000<\/td><td>15D\/30D<\/td><\/tr><tr><td>GYFTY-50 \u00e0 60<\/td><td>50\uff5e60<\/td><td>5<\/td><td>0<\/td><td>9.0<\/td><td>88<\/td><td>800\/1500<\/td><td>500\/1000<\/td><td>15D\/30D<\/td><\/tr><tr><td>GYFTY-62 \u00e0 72<\/td><td>62\uff5e72<\/td><td>6<\/td><td>0<\/td><td>9.5<\/td><td>100<\/td><td>1000\/2000<\/td><td>500\/1000<\/td><td>15D\/30D<\/td><\/tr><tr><td>GYFTY-74 \u00e0 84<\/td><td>74\uff5e84<\/td><td>7<\/td><td>1<\/td><td>10.5<\/td><td>120<\/td><td>1000\/2000<\/td><td>500\/1000<\/td><td>15D\/30D<\/td><\/tr><tr><td>GYFTY-86 \u00e0 96<\/td><td>86\uff5e96<\/td><td>8<\/td><td>0<\/td><td>10.5<\/td><td>120<\/td><td>1500\/2500<\/td><td>500\/1000<\/td><td>15D\/30D<\/td><\/tr><tr><td>GYFTY-98 \u00e0 108<\/td><td>98\uff5e108<\/td><td>9<\/td><td>1<\/td><td>11.5<\/td><td>150<\/td><td>1500\/2500<\/td><td>500\/1000<\/td><td>15D\/30D<\/td><\/tr><tr><td>GYFTY-110 \u00e0 120<\/td><td>110\uff5e120<\/td><td>10<\/td><td>0<\/td><td>12.0<\/td><td>150<\/td><td>1500\/2500<\/td><td>500\/1000<\/td><td>15D\/30D<\/td><\/tr><tr><td>GYFTY-122 \u00e0 144<\/td><td>122 \u00e0 144<\/td><td>12<\/td><td>0<\/td><td>13.0<\/td><td>150<\/td><td>1500\/2500<\/td><td>500\/1000<\/td><td>15D\/30D<\/td><\/tr><tr><td>GYFTY-146 \u00e0 216<\/td><td>146\uff5e216<\/td><td>18<\/td><td>0<\/td><td>13.0<\/td><td>150<\/td><td>1000\/2000<\/td><td>500\/1000<\/td><td>15D\/30D<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Temp\u00e9rature de stockage\/fonctionnement : -40\u2103 \u00e0 + 70\u2103<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">FAQ<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q1 : Quelle est la conception structurelle du c\u00e2ble \u00e0 fibre optique d'ext\u00e9rieur GYFTY et quel est son principal avantage ?<\/strong> <\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>R :<\/strong> Le c\u00e2ble GYFTY se caract\u00e9rise par une conception \u00e0 tubes l\u00e2ches non m\u00e9talliques, comprenant des fibres de 200\/250 \u03bcm enferm\u00e9es dans des tubes l\u00e2ches en plastique \u00e0 haut module de rigidit\u00e9, remplis d'un compos\u00e9 de remplissage r\u00e9sistant \u00e0 l'eau. Il int\u00e8gre un \u00e9l\u00e9ment de renforcement central non m\u00e9tallique en plastique renforc\u00e9 de fibres (FRP) et une gaine ext\u00e9rieure en poly\u00e9thyl\u00e8ne (PE), ce qui le rend insensible aux coups de foudre et aux interf\u00e9rences \u00e9lectromagn\u00e9tiques.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q2 : \u00c0 quelles normes industrielles le c\u00e2ble GYFTY est-il conforme ?<\/strong> <\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>R :<\/strong> Le c\u00e2ble GYFTY est conforme \u00e0 la norme YD\/T 901-2009 ainsi qu'\u00e0 la norme internationale CEI 60794-1.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q3 : Comment le c\u00e2ble GYFTY assure-t-il une protection contre les infiltrations d'eau et les interf\u00e9rences \u00e9lectromagn\u00e9tiques ?<\/strong> <\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>R :<\/strong> Les interf\u00e9rences \u00e9lectromagn\u00e9tiques et radio\u00e9lectriques sont \u00e9limin\u00e9es gr\u00e2ce \u00e0 l'utilisation d'un \u00e9l\u00e9ment de renfort central en FRP enti\u00e8rement di\u00e9lectrique, en lieu et place d'\u00e9l\u00e9ments m\u00e9talliques. La protection contre l'eau est assur\u00e9e par des tubes souples remplis de gel et une \u00e2me de c\u00e2ble enti\u00e8rement remplie de compos\u00e9.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q4 : Quels sont les nombres de fibres, les dimensions des c\u00e2bles et les temp\u00e9ratures de fonctionnement pris en charge ?<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>R :<\/strong> Les principales caract\u00e9ristiques techniques sont les suivantes :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Plage de nombre de fibres :<\/strong> De 2 \u00e0 216 c\u0153urs<\/li>\n\n\n\n<li><strong>Diam\u00e8tre du c\u00e2ble :<\/strong> 9,0 mm (2 \u00e0 60 noyaux) jusqu'\u00e0 13,0 mm (122 \u00e0 216 noyaux)<\/li>\n\n\n\n<li><strong>Poids du c\u00e2ble :<\/strong> de 88 kg\/km \u00e0 150 kg\/km<\/li>\n\n\n\n<li><strong>R\u00e9sistance \u00e0 l'\u00e9crasement :<\/strong> 500 N\/100 mm en charge prolong\u00e9e \/ 1 000 N\/100 mm en charge de courte dur\u00e9e<\/li>\n\n\n\n<li><strong>Plage de temp\u00e9ratures :<\/strong> De -40 \u00b0C \u00e0 +70 \u00b0C pour le stockage et le fonctionnement<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q5 : Qu'est-ce que le prix de r\u00e9f\u00e9rence, et comment puis-je faire une demande de renseignements ?<\/strong> <\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>R :<\/strong> Le prix de r\u00e9f\u00e9rence est de $1,6 USD. Vous pouvez cliquer sur \u201c Ajouter au devis \u201d sur la page du produit pour obtenir des tarifs sur mesure en fonction du volume, ou sur \u201c Demander une d\u00e9mo \u201d pour toute demande d\u2019\u00e9valuation d\u2019\u00e9chantillons.<\/p>","protected":false},"excerpt":{"rendered":"<p>Description The fibers, 200\/250\u03bcm, are positioned in a loose tube made of a high modulus plastic. The tubes are filled with a water-resistant filling compound. A Fiber Reinforced Plastic (FRP) locates in the center of core as a non-metallic strength member. The tubes (and fillers) are stranded around the strength member into a compact and &#8230; <a title=\"C\u00e2ble \u00e0 fibre optique d&#039;ext\u00e9rieur GYFTY\" class=\"read-more\" href=\"https:\/\/firstfibertech.com\/fr\/product\/gyfty\/\" aria-label=\"En savoir plus sur GYFTY Outdoor Fiber Cable\">Lire la suite<\/a><\/p>","protected":false},"featured_media":2494,"template":"","ff_product_cat":[26,67],"class_list":["post-2493","ff_products","type-ff_products","status-publish","has-post-thumbnail","hentry","ff_product_cat-fiber-cabling","ff_product_cat-outdoor-cable-fiber-cabling"],"_links":{"self":[{"href":"https:\/\/firstfibertech.com\/fr\/wp-json\/wp\/v2\/ff_products\/2493","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/firstfibertech.com\/fr\/wp-json\/wp\/v2\/ff_products"}],"about":[{"href":"https:\/\/firstfibertech.com\/fr\/wp-json\/wp\/v2\/types\/ff_products"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/firstfibertech.com\/fr\/wp-json\/wp\/v2\/media\/2494"}],"wp:attachment":[{"href":"https:\/\/firstfibertech.com\/fr\/wp-json\/wp\/v2\/media?parent=2493"}],"wp:term":[{"taxonomy":"ff_product_cat","embeddable":true,"href":"https:\/\/firstfibertech.com\/fr\/wp-json\/wp\/v2\/ff_product_cat?post=2493"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}