{"id":2525,"date":"2026-08-12T07:50:13","date_gmt":"2026-08-12T07:50:13","guid":{"rendered":"https:\/\/firstfibertech.com\/?post_type=ff_products&#038;p=2525"},"modified":"2026-09-01T06:53:37","modified_gmt":"2026-09-01T06:53:37","slug":"chassis-pour-armoires-reseau-et-serveurs-de-la-serie-f2","status":"publish","type":"ff_products","link":"https:\/\/firstfibertech.com\/fr\/product\/f2-series-network-and-server-cabinet-frame\/","title":{"rendered":"Ch\u00e2ssis pour armoires r\u00e9seau et serveurs de la s\u00e9rie F2"},"content":{"rendered":"<h2 class=\"wp-block-heading\">Description<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Ch\u00e2ssis d'armoire r\u00e9seau et serveur de la s\u00e9rie F2 avec porte avant en verre et porte arri\u00e8re en acier<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Normes<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Conforme aux normes ANSI\/EIA RS-310-D, CEI 297-2, DIN 41494 ; PARTIE 1, DIN 41494 ; PARTIE 7 et \u00e0 la norme ETSI.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Fonctionnalit\u00e9s<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Un design raffin\u00e9, alliant dimensions pr\u00e9cises et savoir-faire artisanal ;<\/li>\n\n\n\n<li>Porte d'entr\u00e9e en verre et porte arri\u00e8re en acier ;<\/li>\n\n\n\n<li>Des pieds r\u00e9glables et des roulettes robustes sont disponibles en m\u00eame temps ;<\/li>\n\n\n\n<li>Plusieurs passages de c\u00e2bles verrouillables sur le capot sup\u00e9rieur et le panneau inf\u00e9rieur, de dimensions r\u00e9glables ;<\/li>\n\n\n\n<li>Panneaux lat\u00e9raux amovibles, faciles \u00e0 installer et \u00e0 entretenir ;<\/li>\n\n\n\n<li>Environ entre la moiti\u00e9 et les deux tiers du volume initial une fois mont\u00e9, lorsqu'il est emball\u00e9 \u00e0 plat.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Mat\u00e9riau principal<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Acier lamin\u00e9 \u00e0 froid SPCC ;<\/li>\n\n\n\n<li>\u00c9paisseur : profil\u00e9 de fixation 2,0 mm, \u00e9querre de fixation 1,5 mm, autres \u00e9l\u00e9ments 1,2 mm.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Finition de surface<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>D\u00e9graissage, d\u00e9capage, traitement au phosphor, rev\u00eatement par poudrage ;<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Indice de protection<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>IP20<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Capacit\u00e9 de charge<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Charge statique : 800 kg<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td>Capacit\u00e9 (U)<\/td><td>Largeur<br>(mm)<\/td><td>Profondeur<br>(mm)<\/td><td>Hauteur (mm)<\/td><td>Dimensions de l'emballage<br>L*l*H<\/td><td>Volume<br>(CBM)<\/td><td><\/td><\/tr><tr><td rowspan=\"3\">18<\/td><td rowspan=\"3\">600<\/td><td>600<\/td><td rowspan=\"3\">988<\/td><td>670*670*1028<\/td><td>0.5992<\/td><td>1 plateau<br>1 PDU de 10 A<br>2 ventilateurs<\/td><\/tr><tr><td>800<\/td><td>670*870*1028<\/td><td>0.5992<\/td><td>1 plateau<br>1 PDU de 10 A<br>4 ventilateurs<\/td><\/tr><tr><td>1000<\/td><td>670*1070*1028<\/td><td>0.7370<\/td><td>1 plateau<br>1 PDU de 10 A<br>4 ventilateurs<\/td><\/tr><tr><td rowspan=\"3\">22<\/td><td rowspan=\"3\">600<\/td><td>600<\/td><td rowspan=\"3\">1166<\/td><td>670*670*1196<\/td><td>0.5369<\/td><td>1 plateau<br>1 PDU de 10 A<br>2 ventilateurs<\/td><\/tr><tr><td>800<\/td><td>670*870*1196<\/td><td>0.6971<\/td><td>1 plateau<br>1 PDU de 10 A<br>4 ventilateurs<\/td><\/tr><tr><td>1000<\/td><td>670*1070*1196<\/td><td>0.8574<\/td><td>1 plateau<br>1 PDU de 10 A<br>4 ventilateurs<\/td><\/tr><tr><td rowspan=\"3\">27<\/td><td rowspan=\"3\">600<\/td><td>600<\/td><td rowspan=\"3\">1388<\/td><td>670*670*1418<\/td><td>0.6460<\/td><td>1 plateau<br>1 PDU de 10 A<br>2 ventilateurs<\/td><\/tr><tr><td>800<\/td><td>670*870*1418<\/td><td>0.8266<\/td><td>1 plateau<br>1 PDU de 10 A<br>4 ventilateurs<\/td><\/tr><tr><td>1000<\/td><td>670*1070*1418<\/td><td>1.0166<\/td><td>1 plateau<br>1 PDU de 10 A<br>4 ventilateurs<\/td><\/tr><tr><td rowspan=\"3\">32<\/td><td rowspan=\"3\">600<\/td><td>600<\/td><td rowspan=\"3\">1610<\/td><td>670*670*1640<\/td><td>0.7362<\/td><td>1 plateau<br>1 PDU de 10 A<br>2 ventilateurs<\/td><\/tr><tr><td>800<\/td><td>670*870*1640<\/td><td>0.9560<\/td><td>1 plateau<br>1 PDU de 10 A<br>4 ventilateurs<\/td><\/tr><tr><td>1000<\/td><td>670*1070*1640<\/td><td>1.1757<\/td><td>1 plateau<br>1 PDU de 10 A<br>4 ventilateurs<\/td><\/tr><tr><td rowspan=\"4\">37<\/td><td rowspan=\"4\">600<\/td><td>600<\/td><td rowspan=\"4\">1833<\/td><td>670*670*1863<\/td><td>0.8363<\/td><td>Plateau 3 compartiments<br>1 PDU de 10 A<br>2 ventilateurs<\/td><\/tr><tr><td>800<\/td><td>670*870*1863<\/td><td>1.0859<\/td><td>Plateau 3 compartiments<br>1 PDU de 10 A<br>4 ventilateurs<\/td><\/tr><tr><td>1000<\/td><td>670*1070*1863<\/td><td>1.3356<\/td><td>Plateau 3 compartiments<br>1 PDU de 10 A<br>4 ventilateurs<\/td><\/tr><tr><td>1200<\/td><td>670*1270*1863<\/td><td>1.5852<\/td><td>Plateau 3 compartiments<br>1 PDU de 10 A<br>4 ventilateurs<\/td><\/tr><tr><td rowspan=\"8\">42<\/td><td rowspan=\"4\">600<\/td><td>600<\/td><td rowspan=\"8\">2055<\/td><td>670*670*2085<\/td><td>0.9360<\/td><td>Plateau 3 compartiments<br>1 PDU de 10 A<br>2 ventilateurs<\/td><\/tr><tr><td>800<\/td><td>670*870*2085<\/td><td>1.2153<\/td><td>Plateau 3 compartiments<br>1 PDU de 10 A<br>4 ventilateurs<\/td><\/tr><tr><td>1000<\/td><td>670*1070*2085<\/td><td>1.4947<\/td><td>Plateau 3 compartiments<br>1 PDU de 10 A<br>4 ventilateurs<\/td><\/tr><tr><td>1200<\/td><td>670*1270*2085<\/td><td>1.7741<\/td><td>Plateau 3 compartiments<br>1 PDU de 10 A<br>4 ventilateurs<\/td><\/tr><tr><td rowspan=\"4\">800<\/td><td>600<\/td><td>870*670*2085<\/td><td>1.2513<\/td><td>Plateau 3 compartiments<br>1 PDU de 10 A<br>2 ventilateurs<\/td><\/tr><tr><td>800<\/td><td>870*870*2085<\/td><td>1.5781<\/td><td>Plateau 3 compartiments<br>1 PDU de 10 A<br>4 ventilateurs<\/td><\/tr><tr><td>1000<\/td><td>870*1070*2085<\/td><td>1.9409<\/td><td>Plateau 3 compartiments<br>1 PDU de 10 A<br>4 ventilateurs<\/td><\/tr><tr><td>1200<\/td><td>870*1270*2085<\/td><td>2.3037<\/td><td>Plateau 3 compartiments<br>1 PDU de 10 A<br>4 ventilateurs<\/td><\/tr><tr><td rowspan=\"4\">47<\/td><td rowspan=\"4\">600<\/td><td>600<\/td><td rowspan=\"4\">2277<\/td><td>670*670*2307<\/td><td>1.0356<\/td><td>Plateau 3 compartiments<br>1 PDU de 10 A<br>2 ventilateurs<\/td><\/tr><tr><td>800<\/td><td>670*870*2307<\/td><td>1.3448<\/td><td>Plateau 3 compartiments<br>1 PDU de 10 A<br>4 ventilateurs<\/td><\/tr><tr><td>1000<\/td><td>670*1070*2307<\/td><td>1.6539<\/td><td>Plateau 3 compartiments<br>1 PDU de 10 A<br>4 ventilateurs<\/td><\/tr><tr><td>1200<\/td><td>670*1270*2307<\/td><td>1.9630<\/td><td>Plateau 3 compartiments<br>1 PDU de 10 A<br>4 ventilateurs<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">FAQ<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q1 : \u00c0 quelles normes industrielles l'armoire de la s\u00e9rie F2 est-elle conforme ?<\/strong> <\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>R :<\/strong> La s\u00e9rie F2 est conforme aux normes ANSI\/EIA RS-310-D, CEI 297-2, DIN 41494 (parties 1 et 7) et ETSI.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q2 : Quels sont le mat\u00e9riau de fabrication, l'indice de protection et la capacit\u00e9 de charge de ce ch\u00e2ssis d'armoire ?<\/strong> <\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>R :<\/strong> Il est fabriqu\u00e9 en acier lamin\u00e9 \u00e0 froid SPCC (profil\u00e9 de fixation : 2,0 mm, \u00e9querre de fixation : 1,5 mm, autres pi\u00e8ces : 1,2 mm) et pr\u00e9sente une finition de surface par thermolaquage. Il b\u00e9n\u00e9ficie d'un indice de protection IP20 et supporte une charge statique maximale de 800 kg.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q3 : Quelles sont les tailles et les couleurs disponibles pour la s\u00e9rie F2 ?<\/strong> <\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>R :<\/strong> Les capacit\u00e9s vont de 18U \u00e0 47U (18U, 22U, 27U, 32U, 37U, 42U et 47U), avec des largeurs de 600 mm ou 800 mm et des profondeurs allant de 600 mm \u00e0 1 200 mm. Les couleurs disponibles sont le noir (RAL 9004) et le gris (RAL 7035).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q4 : Quelles sont les principales fonctionnalit\u00e9s qui facilitent l'installation et l'exp\u00e9dition ?<\/strong> <\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>R :<\/strong> Il est \u00e9quip\u00e9 d'une porte avant en verre, d'une porte arri\u00e8re en acier, de panneaux lat\u00e9raux amovibles, de passages de c\u00e2bles r\u00e9glables et verrouillables sur le capot sup\u00e9rieur et le panneau inf\u00e9rieur, et permet d'utiliser simultan\u00e9ment des pieds de mise \u00e0 niveau et des roulettes robustes. De plus, sa conception en kit r\u00e9duit le volume d'exp\u00e9dition de la moiti\u00e9 \u00e0 deux tiers par rapport aux unit\u00e9s enti\u00e8rement assembl\u00e9es.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q5 : Quels sont les accessoires standard fournis avec l'armoire ?<\/strong> <\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>R :<\/strong> En fonction de la profondeur et des dimensions de l'armoire, les unit\u00e9s sont \u00e9quip\u00e9es de plateaux pour mat\u00e9riel (1 ou 3), d'une unit\u00e9 de distribution d'alimentation (PDU) de 10 A et de 2 ou 4 ventilateurs de refroidissement.<\/p>","protected":false},"excerpt":{"rendered":"<p>Description : Ch\u00e2ssis d'armoire r\u00e9seau et serveur de la s\u00e9rie F2 avec porte avant en verre et porte arri\u00e8re en acier Normes Caract\u00e9ristiques Mat\u00e9riau principal Finition de surface Indice de protection Capacit\u00e9 de charge Capacit\u00e9 (U) Largeur(mm) Profondeur (mm) Hauteur (mm) Dimensions de l'emballage L*P*H Volume (m\u00b3) 18 600 600 988 670*670 \u00d7 1 028 0,5992 1 x plateau, 1 x PDU 10 A, 2 x ventilateurs 800 670 \u00d7 870 \u00d7 1 028 0,5992 1 x plateau, 1 x 10 A \u2026 <a title=\"Ch\u00e2ssis pour armoires r\u00e9seau et serveurs de la s\u00e9rie F2\" class=\"read-more\" href=\"https:\/\/firstfibertech.com\/fr\/product\/f2-series-network-and-server-cabinet-frame\/\" aria-label=\"En savoir plus sur F2 Series Network and Server Cabinet Frame\">Lire la suite<\/a><\/p>","protected":false},"featured_media":2526,"template":"","ff_product_cat":[29,86],"class_list":["post-2525","ff_products","type-ff_products","status-publish","has-post-thumbnail","hentry","ff_product_cat-fiber-cable-management","ff_product_cat-server-network-frame"],"_links":{"self":[{"href":"https:\/\/firstfibertech.com\/fr\/wp-json\/wp\/v2\/ff_products\/2525","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/firstfibertech.com\/fr\/wp-json\/wp\/v2\/ff_products"}],"about":[{"href":"https:\/\/firstfibertech.com\/fr\/wp-json\/wp\/v2\/types\/ff_products"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/firstfibertech.com\/fr\/wp-json\/wp\/v2\/media\/2526"}],"wp:attachment":[{"href":"https:\/\/firstfibertech.com\/fr\/wp-json\/wp\/v2\/media?parent=2525"}],"wp:term":[{"taxonomy":"ff_product_cat","embeddable":true,"href":"https:\/\/firstfibertech.com\/fr\/wp-json\/wp\/v2\/ff_product_cat?post=2525"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}