{"id":3676,"date":"2026-08-27T06:52:52","date_gmt":"2026-08-27T06:52:52","guid":{"rendered":"https:\/\/firstfibertech.com\/?p=3676"},"modified":"2026-08-28T11:36:34","modified_gmt":"2026-08-28T11:36:34","slug":"fc1500-user-guide","status":"publish","type":"post","link":"https:\/\/firstfibertech.com\/fr\/blog\/fc1500-user-guide\/","title":{"rendered":"Guide d'utilisation du FC1500"},"content":{"rendered":"<p class=\"wp-block-paragraph\">PREFACE<br>Thank you very much for purchasing and using this series of optical time domain reflectometers.\u00a0<br>This manual mainly contains the common operation and maintenance information of the instru<br>ment, as well as the common troubleshooting guide and other information. In order to facilitate\u00a0<br>your use, please read the contents of this manual carefully before operating the instrument, and\u00a0<br>follow the instructions of this manual correctly.<br>This manual is only used with this instrument. Any company or person is allowed to tamper, copy\u00a0<br>and disseminate the contents of this manual for commercial purposes without the authorization of\u00a0<br>the company.<br>The contents of this manual are subject to change without notice. If you have any questions,\u00a0<br>please call the supplier, we will provide you with the best service!<br>Compte tenu de la n\u00e9cessit\u00e9 d'am\u00e9liorer la conception, le contenu est susceptible d'\u00eatre modifi\u00e9 sans pr\u00e9avis.<br>R\u00e9sum\u00e9<br>This series of OTDR is a multi-functional optical measuring instrument, which \u00a0OTDR, \u00a0event map, visual fault location,\u00a0<br>RJ45 Test(cable line length \u3001sequence test\u3001cable tracking),optical multimeter(Laser Source\u3001optical loss test),optical power\u00a0<br>meter, end face detection,and other functions. It has touch screen and heys. It is the right assistant for optical cable construc<br>tion, installation and maintenance, project acceptance and on-site repair<br>Avertissement<br>When using the instrument, do not look directly at the laser output port or the end of the optical fiber with your eyes, avoid\u00a0<br>eye damage!Dual wavelength testing of 1310nm&amp;1550nm is prohibited online, as forced use may cause damage to internal\u00a0<br>components of the instrument!Any change or modification not explicitly permitted in this manual will deprive you of the right\u00a0<br>to operate the equipment. To reduce the risk of fire or electric shock, do not expose the equipment to thunderstorm or humid\u00a0<br>environment. In order to prevent electric shock, please do not open the shell. It must be repaired by qualified personnel\u00a0<br>designated by the manufacturer.<br>Attentions<br>Battery: The battery is a special polymer lithium battery, the charging voltage is 5V\/2A, and the charging temperature\u00a0<br>range is -5\u2103~+45\u2103. When the ambient temperature is too high, the charging will automatically terminate. The battery should\u00a0<br>be charged every one month to avoid long storage time and failure of battery due to self discharge. The temperature range of\u00a0<br>battery during long-term storage is: &#8211; 20 \u2103 ~ 50 \u2103.<br>Please use the special adapter attached with the instrument box and use the external power supply in strict accordance\u00a0<br>with the specifications, otherwise the equipment may be damaged.<br>End Face Cleaning: Before testing, clean the end face of the tested fiber joint with alcohol cotton.<br>LCD screen: The display of this series of instruments is 4.3 inch color LCD. In order to maintain good viewing effect, please\u00a0<br>keep the LCD screen clean. When cleaning, wipe the LCD screen with soft fabric.<br>Attentions<br>Guarantee description:The whole machine is guaranteed for 36 months. The battery, charging adapter and optical\u00a0<br>interface consumables are guaranteed for 6 months. The warranty date shall be postponed one month from the date of \u00a0<br>manufacture.<br>Host<br>Top<br>\u2460 OTDR port<br>\u2461 VFL port<br>\u2462 OPM port<br>\u2463 Flashlight<br>\u2464Type-C<br>\u2465 TF\uff08Mico SD\uff09card<br>\u2466 USB<br>Main view<br>\u2460 Dust cover<br>\u2461 Function keys<br>\u2462 4.3 inch color LCD<br>\u2463 Charging indicator<br>\u2464 Power on status indicator<br>Bottom<br>\u2460 RJ45 Sequence test port<br>\u2461 RJ45 Cable line length\/cable tracking port<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"619\" height=\"1024\" src=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-instrument-diagram-619x1024.webp\" alt=\"FC1500 OTDR multi-functional optical measuring instrument diagram\" class=\"wp-image-3677\" srcset=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-instrument-diagram-619x1024.webp 619w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-instrument-diagram-181x300.webp 181w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-instrument-diagram-7x12.webp 7w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-instrument-diagram.webp 646w\" sizes=\"auto, (max-width: 619px) 100vw, 619px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Function buttons<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"570\" src=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-user-guide-1024x570.webp\" alt=\"FC1500 OTDR optical time domain reflectometer user interface controls\" class=\"wp-image-3678\" srcset=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-user-guide-1024x570.webp 1024w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-user-guide-300x167.webp 300w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-user-guide-768x428.webp 768w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-user-guide-1536x856.webp 1536w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-user-guide-18x10.webp 18w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-user-guide.webp 1641w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Main interface<br>After booting up, enter the main menu with a total of 9\u00a0<br>functional modules. Press the directional keys to select the\u00a0<br>module, then press the &#8220;OK&#8221; key or directly press the func<br>tion icon to enter the corresponding functional interface<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"822\" height=\"329\" src=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-status-bar-8kkG.webp\" alt=\"FC1500 OTDR status bar VFL LS battery\" class=\"wp-image-3679\" srcset=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-status-bar-8kkG.webp 822w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-status-bar-8kkG-300x120.webp 300w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-status-bar-8kkG-768x307.webp 768w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-status-bar-8kkG-18x7.webp 18w\" sizes=\"auto, (max-width: 822px) 100vw, 822px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Press the &#8220;Shortcut Menu&#8221; to enter the operation interface,\u00a0<br>and press different icons to achieve the corresponding\u00a0<br>operation functions.<br>Key operation\uff1aSelect the function menu up, down, left,\u00a0<br>right, and OK to enter the function item.<br>Screenshot: Capture the current interface, and the image\u00a0<br>will be automatically saved inside the instrument. The file\u00a0<br>name is the time when the screenshot was generated<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"827\" height=\"935\" src=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-instrument-interface.webp\" alt=\"FC1500 OTDR optical measuring instrument interface\" class=\"wp-image-3680\" srcset=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-instrument-interface.webp 827w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-instrument-interface-265x300.webp 265w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-instrument-interface-768x868.webp 768w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-instrument-interface-11x12.webp 11w\" sizes=\"auto, (max-width: 827px) 100vw, 827px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">OTDR<br>Select the testing wavelength, range, pulse width, time, and\u00a0<br>mode. Different ranges correspond to different selectable\u00a0<br>pulse widths.<br>Advanced settings: Analysis parameters, qualification\u00a0<br>criteria, and other parameter settings;<br>Quick setup:<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"687\" height=\"60\" src=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-interface-functions.webp\" alt=\"FC1500 OTDR Event Map List Curve Switching Interface\" class=\"wp-image-3682\" srcset=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-interface-functions.webp 687w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-interface-functions-300x26.webp 300w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-interface-functions-8x2.webp 18w\" sizes=\"auto, (max-width: 687px) 100vw, 687px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Fonctionnement de la courbe<br>Curve scaling and dragging:Touch screen gesture oper<br>ation<br>Restore initial curve:Click on the screen 1:1<br>Move cursor:Drag A or B<br>\u00a0\u00a0<br>Physical button operation:<br>SET \uff1aDelete<br>ESC \uff1aReturn<br>\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \uff1aChoice<br>\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \uff1aExport<br>\u00a0 OK \u00a0\uff1aConfirm<br>Gain events \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \uff1aFiber fusion points of different specifications<br>Down event \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \uff1aMelting point or bending loss<br>Reflective \u00a0event \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \uff1aConnectors, square flange, SC, ST, LC connectors, etc<br>Fiber end \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0\uff1aEnd of link<br>10 Event map<br>This function is completely one click automatic testing,\u00a0<br>displaying the length, connector type, breakpoint position\u00a0<br>and other information of the measured optical fiber link in\u00a0<br>a graphical form, with clear and easy to understand\u00a0<br>results.<br>Starting point of the link<br>Drop event, mostly involving fusion points<br>Connector, square flange, SC, ST, LC connectors, etc<br>Fiber optic macro bending, high loss bending point<br>End of link<br>Physical button operation:<br>SET\uff1aPop up options for setting test parameters and\u00a0<br>automatic saving<br>ESC: return<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"51\" height=\"45\" src=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-guide-media.webp\" alt=\"FC1500 OTDR user guide media playback\" class=\"wp-image-3683\" srcset=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-guide-media.webp 51w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-guide-media-14x12.webp 14w\" sizes=\"auto, (max-width: 51px) 100vw, 51px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\uff1aTesting and Stopping<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"57\" height=\"47\" src=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-troubleshooting.webp\" alt=\"FC1500 OTDR optical fiber troubleshooting symbol\" class=\"wp-image-3684\" srcset=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-troubleshooting.webp 57w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-troubleshooting-15x1.webp 15w\" sizes=\"auto, (max-width: 57px) 100vw, 57px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\uff1aCursor switching (move cursor position with left and right buttons), zoom in mode (zoom in with up, down, left and right buttons)<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Event type:<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"878\" height=\"215\" src=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-event-types.webp\" alt=\"FC1500 OTDR trace event definitions\" class=\"wp-image-3685\" srcset=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-event-types.webp 878w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-event-types-300x73.webp 300w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-event-types-768x188.webp 768w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-event-types-18x4.webp 18w\" sizes=\"auto, (max-width: 878px) 100vw, 878px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"824\" height=\"497\" src=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-fiber-test-display.webp\" alt=\"FC1500 OTDR optical fiber test measurement display\" class=\"wp-image-3686\" srcset=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-fiber-test-display.webp 824w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-fiber-test-display-300x181.webp 300w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-fiber-test-display-768x463.webp 768w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-fiber-test-display-18x12.webp 18w\" sizes=\"auto, (max-width: 824px) 100vw, 824px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">OTDR-Set test parameters<br>Wave: The wavelength at which light waves are emitted.<br>Range: Select the corresponding predefined range based on the\u00a0<br>actual length of the optical fiber, which must be greater than the\u00a0<br>length of the measured optical fiber, usually set to about twice the\u00a0<br>longueur de la fibre optique mesur\u00e9e<br>Pulse : Refers to the time width of the optical pulse signal emitted\u00a0<br>during measurement. The larger the pulse width, the stronger the\u00a0<br>optical power injected into the fiber, the stronger the backscatter\u00a0<br>signal of the fiber, and the farther the OTDR can effectively detect.\u00a0<br>However, a large pulse width can cause saturation of the initial reflection signal, resulting in a large blind spot. The selection of pulse width is related to the length of the measuring fiber. The\u00a0<br>longer the length, the greater the pulse width, which can only be modified in real-time\/average measurement mode.<br>Mode: The equipment is divided into three modes: automatic testing, average testing, and real-time testing. Automatic testing auto<br>matically selects testing conditions without the need for manual selection. Average testing and real-time testing require manual\u00a0<br>selection of testing conditions.<br>Time: In the average measurement mode, the longer the detection time, the better the signal-to-noise ratio improvement of the\u00a0<br>signal, and the more accurate the test results. Users should choose the measurement time reasonably, and the measurement time is\u00a0<br>directly proportional to the measurement dynamics.<br>Unit: Select the desired unit, with three options available: km, kft, and mi (miles).<br>Auto save: Whether to automatically save the test file after testing is completed.<br>Refractive Index: Determined by the inherent characteristics of optical fibers and provided by cable or fiber manufacturers, refrac<br>tive index is a key parameter for calculating distance and cannot be set arbitrarily. The range of refractive index is 1-2.<br>Key operation: Press the SET key to enter parameter settings, select parameters up, down, left, right, and OK to confirm the parameters.<br>OTDR-Threshold\/Criterion<br>Threshold setting<br>Event loss threshold: Set the loss threshold for the connection\u00a0<br>points, fusion points, or macro bends in the link that can be tested,\u00a0<br>between 0.01dB and 9.99dB, with a default of 0.20dB. Events exceed<br>ing the set threshold will be listed in the event table, while events\u00a0<br>below the threshold will be ignored.<br>Reflection threshold: Set the return loss threshold for the link reflec<br>tion events that can be tested, between -99.99dB~1.00dB, with a\u00a0<br>default of -40.00dB.<br>End threshold: Set the loss value at the end of the link that can be\u00a0<br>tested, between 1dB and 30dB, with a default of 10dB.<br>Qualification criteria<br>Set a judgment value for the average loss of connection\/fusion\/bend<br>ing\/link. If it is less than the judgment value, it is judged as &#8220;PASS&#8221;,\u00a0<br>otherwise it is &#8220;FAIL&#8221;.<br>Connection loss: Reflection event, referring to flange, SC, LC and\u00a0<br>other joints;<br>Welding loss: Non reflective event, often referring to the welding\u00a0<br>point;<br>Bending loss: Non reflective event caused by fiber bending, requiring\u00a0<br>simultaneous testing of two wavelengths;<br>Link loss: The total loss threshold value of the tested link.<br>Average loss: The loss value per kilometer of the tested link.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"728\" height=\"905\" src=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-parameters-settings-wnuQ.webp\" alt=\"FC1500 OTDR analysis pass\/fail parameters settings\" class=\"wp-image-3687\" srcset=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-parameters-settings-wnuQ.webp 728w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-parameters-settings-wnuQ-241x300.webp 241w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-parameters-settings-wnuQ-10x12.webp 10w\" sizes=\"auto, (max-width: 728px) 100vw, 728px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Courbe OTDR<br>Selecting the correct parameter settings and completing\u00a0<br>the test will display test results such as curves and event\u00a0<br>lists.<br>Curve scaling<br>Touch screen gesture operation enters zoom out and\u00a0<br>zoom in mode.<br>Event List<br>List: The measurement results are displayed in the form of\u00a0<br>a list.<br>Total length of optical cable: The total length of the\u00a0<br>currently tested link<br>Total loss: The total loss of the currently tested link<br>Average loss: The loss per kilometer of the currently\u00a0<br>tested link<br>Dans la liste des \u00e9v\u00e9nements :<br>Serial number: The order of the current event<br>Type: The type of the current event point<br>Distance: The location of the current event point<br>Section: The distance between the previous event point\u00a0<br>and the current event point<br>Loss: The loss value at the current event point<br>Slope: Loss value per kilometer from the starting point to the\u00a0<br>current event point<br>Reflection: Return loss value of the current event point<br>Total loss: The cumulative loss value from the starting point to\u00a0<br>the current event point<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"728\" height=\"905\" src=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-parameters-settings.webp\" alt=\"FC1500 OTDR analysis pass fail parameters settings\" class=\"wp-image-3688\" srcset=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-parameters-settings.webp 728w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-parameters-settings-241x300.webp 241w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-parameters-settings-10x12.webp 10w\" sizes=\"auto, (max-width: 728px) 100vw, 728px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">OTDR-File save<br>After the measurement is completed, press \u3010Save\u3011 to\u00a0<br>save the file, enter the file name, and press &#8220;Enter&#8221; to save\u00a0<br>the file. The file is saved in a folder named after the\u00a0<br>current date.<br>Auto save: Open the file auto save function, and the file\u00a0<br>name will be automatically generated according to the\u00a0<br>rules.<br>Naming Type:<br>File Name+FiberID, with FiberID increasing in sequence;<br>File Name+Range+FiberID, with FiberID increasing in\u00a0<br>sequence;<br>File Name+Range+Pulse+FiberID, with FiberID increasing in sequence.<br>File Name: Manually enter the file name.<br>FiberID: Manually enter the fiber number.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"820\" height=\"491\" src=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-save-parameters.webp\" alt=\"FC1500 OTDR save parameters user interface\" class=\"wp-image-3689\" srcset=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-save-parameters.webp 820w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-save-parameters-300x180.webp 300w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-save-parameters-768x460.webp 768w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-save-parameters-18x12.webp 18w\" sizes=\"auto, (max-width: 820px) 100vw, 820px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u00a0OTDR-File operation<br>File operation<br>All test curves are saved in the TF card that comes\u00a0<br>standard with the instrument.Press \u3010 File\u3011 to enter the file\u00a0<br>operation interface, where you can open, delete, and\u00a0<br>rename files.<br>\u3010 Open \u3011 Support for comparing up to 4 curves.<br>The internal test sor data of the machine TF card can be\u00a0<br>exported through a USB flash drive.<br>Physical button operation:<br>SET \uff1aDelete<br>ESC \uff1aReturn<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"224\" height=\"169\" src=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-operation-controls-yK9x.webp\" alt=\"FC1500 OTDR operation control symbols\" class=\"wp-image-3690\" srcset=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-operation-controls-yK9x.webp 224w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-operation-controls-yK9x-16x12.webp 16w\" sizes=\"auto, (max-width: 224px) 100vw, 224px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"825\" height=\"500\" src=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-file-management.webp\" alt=\"FC1500 OTDR device catalog file management\" class=\"wp-image-3691\" srcset=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-file-management.webp 825w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-file-management-300x182.webp 300w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-file-management-768x465.webp 768w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-file-management-18x12.webp 18w\" sizes=\"auto, (max-width: 825px) 100vw, 825px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u00a0Event map<br>This function is completely one click automatic testing,\u00a0<br>displaying the length, connector type, breakpoint position\u00a0<br>and other information of the measured optical fiber link in\u00a0<br>a graphical form, with clear and easy to understand\u00a0<br>results.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"762\" height=\"451\" src=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-fiber-event-symbols.webp\" alt=\"FC1500 OTDR fiber optic link event symbols\" class=\"wp-image-3692\" srcset=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-fiber-event-symbols.webp 762w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-fiber-event-symbols-300x178.webp 300w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-fiber-event-symbols-18x12.webp 18w\" sizes=\"auto, (max-width: 762px) 100vw, 762px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Physical button operation:<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"714\" height=\"127\" src=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-controls.webp\" alt=\"FC1500 OTDR operation control symbols\" class=\"wp-image-3693\" srcset=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-controls.webp 714w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-controls-300x53.webp 300w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-controls-18x3.webp 18w\" sizes=\"auto, (max-width: 714px) 100vw, 714px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Warning:Please do not make online test except online wavelengths!<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"825\" height=\"491\" src=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-event-loss.webp\" alt=\"FC1500 OTDR fiber event loss distance measurement\" class=\"wp-image-3694\" srcset=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-event-loss.webp 825w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-event-loss-300x179.webp 300w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-event-loss-768x457.webp 768w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-event-loss-18x12.webp 18w\" sizes=\"auto, (max-width: 825px) 100vw, 825px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u00a0OPM<br>Used for signal power testing and insertion loss testing of\u00a0<br>various devices and optoelectronic components. Can\u00a0<br>identify and measure the power of 270Hz\/1kHz\/2kHz\u00a0<br>frequency light.<br>Wavelength: Switching the testing wavelength of the\u00a0<br>power meter<br>Calibration: Enter calibration mode<br>Reference: Set the current power as the reference power<br>Zeroing: Reference power set to zero<br>Physical button operation:<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"452\" height=\"198\" src=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-wavelength-power-settings.webp\" alt=\"FC1500 OTDR wavelength switching power reference settings\" class=\"wp-image-3695\" srcset=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-wavelength-power-settings.webp 452w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-wavelength-power-settings-300x131.webp 300w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-wavelength-power-settings-18x8.webp 18w\" sizes=\"auto, (max-width: 452px) 100vw, 452px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">The conversion relations of absolute power, relative power and\u00a0<br>linear power are as follows:<br>PAbs.Pow=10lgPLin.Pow\/1mW<br>PRel.Pow=PAbs.Pow-PRef.Pow<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"839\" height=\"497\" src=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-optical-power-display.webp\" alt=\"FC1500 OTDR optical power meter display 1490nm\" class=\"wp-image-3696\" srcset=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-optical-power-display.webp 839w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-optical-power-display-300x178.webp 300w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-optical-power-display-768x455.webp 768w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-optical-power-display-18x12.webp 18w\" sizes=\"auto, (max-width: 839px) 100vw, 839px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u00a0VFL<br>VFL, abbreviated as VFL, injects visible light (red light) into\u00a0<br>the optical fiber and observes the leakage position on the\u00a0<br>measured fiber to conveniently and accurately determine\u00a0<br>the location of the fiber fault point. Suitable for detecting\u00a0<br>near end fault points and high loss sections caused by\u00a0<br>micro bends in bare optical fibers, fiber jumpers, and\u00a0<br>other optical fibers and cables that can leak red light.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"114\" height=\"92\" src=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-continuous-wave.webp\" alt=\"FC1500 OTDR Continuous Wave mode icon\" class=\"wp-image-3697\" srcset=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-continuous-wave.webp 114w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-continuous-wave-15x12.webp 15w\" sizes=\"auto, (max-width: 114px) 100vw, 114px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\uff1aClick to turn on\/off the red light and output it in<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">continuous mode<br>1Hz\uff1aRed light flashes at a frequency of 1Hz<br>2Hz\uff1aRed light flashes at a frequency of 2Hz<br>Physical button operation:<br>OK \u00a0\uff1aTesting and Stopping<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"408\" height=\"45\" src=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-frequency-control.webp\" alt=\"FC1500 OTDR flashing frequency switch function\" class=\"wp-image-3698\" srcset=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-frequency-control.webp 408w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-frequency-control-300x33.webp 300w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-frequency-control-18x2.webp 18w\" sizes=\"auto, (max-width: 408px) 100vw, 408px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">ESC\uff1aReturn<br>Warning: Avoid looking directly at the laser output port, as the\u00a0<br>laser can cause damage to the retina of the human eye!<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"827\" height=\"498\" src=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-vfl-650nm-settings.webp\" alt=\"FC1500 OTDR VFL 650nm visual fault locator interface\" class=\"wp-image-3699\" srcset=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-vfl-650nm-settings.webp 827w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-vfl-650nm-settings-300x181.webp 300w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-vfl-650nm-settings-768x462.webp 768w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-vfl-650nm-settings-18x12.webp 18w\" sizes=\"auto, (max-width: 827px) 100vw, 827px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Multimeter-LS<br>LS, abbreviated as LS, can output laser with the same\u00a0<br>wavelength as OTDR function, used for parameter testing\u00a0<br>of telecommunications, cable TV, and LAN optical cables;\u00a0<br>Insertion loss, isolation, and return loss testing of optical\u00a0<br>passive components; Detector wavelength responsivity\u00a0<br>testing, etc.<br>There are five working modes of the light source\uff1aCW\u3001<br>270Hz\u3001330Hz\u30011kHz and 2kHz\u3002<br>Open: Turn on the light source<br>Wavelength: Switching the wavelength of the light source<br>Mode: Switch light source mode, CW, 270Hz, 330Hz, 1kHz,\u00a0<br>and 2kHz<br>Physical button operation:<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"782\" height=\"129\" src=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-operation-controls-IS72.webp\" alt=\"FC1500 OTDR wavelength test mode controls\" class=\"wp-image-3700\" srcset=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-operation-controls-IS72.webp 782w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-operation-controls-IS72-300x49.webp 300w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-operation-controls-IS72-768x127.webp 768w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-operation-controls-IS72-18x3.webp 18w\" sizes=\"auto, (max-width: 782px) 100vw, 782px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Warning :Avoid looking directly at the laser output port, as the<br>laser can cause damage to the retina of the human eye!<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"828\" height=\"505\" src=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-1550nm-laser-source.webp\" alt=\"FC1500 OTDR laser source 1550nm CW settings\" class=\"wp-image-3701\" srcset=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-1550nm-laser-source.webp 828w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-1550nm-laser-source-300x183.webp 300w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-1550nm-laser-source-768x468.webp 768w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-1550nm-laser-source-18x12.webp 18w\" sizes=\"auto, (max-width: 828px) 100vw, 828px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u00a0Multimeter-Insertion loss<br>Used to test the insertion loss value of optical passive\u00a0<br>components.<br>The steps for measuring optical loss are as follows:<br>1) First, connect the LS and OPM optical interfaces with a\u00a0<br>standard jumper, press \u3010 Enable \u3011, and after the power\u00a0<br>stabilizes, press \u3010 Reference \u3011;<br>2) Use standard jumpers to connect the tested component\u00a0<br>to the LS and OPM optical interfaces, press \u3010 Enable \u3011, and\u00a0<br>the &#8216;Relative Power&#8217; will be the insertion loss of the tested\u00a0<br>component.<br>Physical button operation:<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"381\" height=\"173\" src=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-operation-controls.webp\" alt=\"FC1500 OTDR operation controls: testing, wavelength switching, return\" class=\"wp-image-3702\" srcset=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-operation-controls.webp 381w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-operation-controls-300x136.webp 300w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-operation-controls-18x8.webp 18w\" sizes=\"auto, (max-width: 381px) 100vw, 381px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"828\" height=\"500\" src=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-optical-loss-measurement.webp\" alt=\"FC1500 OTDR optical power loss measurement\" class=\"wp-image-3703\" srcset=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-optical-loss-measurement.webp 828w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-optical-loss-measurement-300x181.webp 300w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-optical-loss-measurement-768x464.webp 768w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-optical-loss-measurement-18x12.webp 18w\" sizes=\"auto, (max-width: 828px) 100vw, 828px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">RJ45 Test-RJ45 cable line length \/sequence test<br>Line sequence measurement: During testing, connect the remote end\u00a0<br>of the accessory to the other end of the network cable. The testing\u00a0<br>modes are direct connection and interleaved connection. Click to start\u00a0<br>testing and the order of the network cables will be displayed.<br>Wire length test: RJ45 wire length is used to test the length and status\u00a0<br>(open circuit, short circuit) of Ethernet cables, and supports live testing.<br>The testing distance range is 1-300m, with a distance deviation of\u00a0<br>approximately \u00b1 1.5m.<br>There are two types of wires for RJ45 connectors: straight through wires\u00a0<br>and patch cords.<br>Network cable standard: T568A\/T568B, the color order of the network\u00a0<br>cable varies depending on the standard.<br>Physical button operation:<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"671\" height=\"153\" src=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-testing-network-cable.webp\" alt=\"FC1500 OTDR testing network cable T568A T568B\" class=\"wp-image-3704\" srcset=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-testing-network-cable.webp 671w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-testing-network-cable-300x68.webp 300w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-testing-network-cable-18x4.webp 18w\" sizes=\"auto, (max-width: 671px) 100vw, 671px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Warning:The line length\/line sequence interface is designated as the instrument interface displayed in yellow.\u00a0<br>Please do not connect it incorrectly to cause equipment damage!<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"691\" height=\"861\" src=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-t568a-lan-test.webp\" alt=\"FC1500 OTDR T568A LAN cable test\" class=\"wp-image-3705\" srcset=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-t568a-lan-test.webp 691w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-t568a-lan-test-241x300.webp 241w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-t568a-lan-test-10x12.webp 10w\" sizes=\"auto, (max-width: 691px) 100vw, 691px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">RJ45 Test-RJ45 cable tracking<br>RJ45 cable tracking test<br>After the line finding function is activated, touch the\u00a0<br>tested cable with the line finder and hear a continuous\u00a0<br>&#8220;beep beep beep&#8221; sound, which is the cable being\u00a0<br>searched for.<br>This equipment is pressure resistant and heat-resistant,\u00a0<br>and can be directly used for live wire tracing. Ethernet\u00a0<br>switches, routers, and other low-voltage equipment with\u00a0<br>a DC voltage less than 60V.<br>The line finding method of this machine is based on\u00a0<br>digital radar, with strong anti-interference ability. The\u00a0<br>frequency of the prompt sound varies according to the\u00a0<br>distance of the target.<br>Physical button operation:\u00a0 \u00a0 \u00a0<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"461\" height=\"109\" src=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-testing-stopping-return-controls.webp\" alt=\"FC1500 OTDR testing stopping return operation controls\" class=\"wp-image-3706\" srcset=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-testing-stopping-return-controls.webp 461w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-testing-stopping-return-controls-300x71.webp 300w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-testing-stopping-return-controls-18x4.webp 18w\" sizes=\"auto, (max-width: 461px) 100vw, 461px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Warning:The wire tracing interface is designated as the instru<br>ment interface displayed in yellow. Please do not\u00a0<br>connect it incorrectly to cause equipment damage!<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"834\" height=\"504\" src=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-network-live-test.webp\" alt=\"FC1500 OTDR network cable live testing\" class=\"wp-image-3707\" srcset=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-network-live-test.webp 834w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-network-live-test-300x181.webp 300w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-network-live-test-768x464.webp 768w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-network-live-test-18x12.webp 18w\" sizes=\"auto, (max-width: 834px) 100vw, 834px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u00a0End face detection<br>End face inspection can achieve real-time monitoring\u00a0<br>of the cleanliness of fiber optic joints.<br>Step 1\uff1aConnect the end face detection probe to the\u00a0<br>USB-A interface;<br>Step 2\uff1aClick to start;<br>Step 3\uff1aConnect the tested fiber optic cable and check\u00a0<br>the cleanliness of the tested end face in real time.<br>Physical button operation:<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"461\" height=\"109\" src=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-testing-controls.webp\" alt=\"FC1500 OTDR testing and return controls\" class=\"wp-image-3708\" srcset=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-testing-controls.webp 461w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-testing-controls-300x71.webp 300w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-testing-controls-18x4.webp 18w\" sizes=\"auto, (max-width: 461px) 100vw, 461px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Time:Set instrument time and date<br>Power management:Strong light mode, sound, pow<br>er-saving settings\uff0cBacklight brightness\uff080~100%\uff09,<br>Automatic shutdown (shutdown\/5\/15\/30\/60\/120 minutes)<br>Connection: Bluetooth connection, Type-C connection<br>Language\uff1aDisplay the native language type<br>Factory mode\uff1aUpgrade (local software update), restore\u00a0<br>factory settings (restore default parameter values)<br>About this machine\uff1aView local information and alarm\u00a0<br>records<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"833\" height=\"497\" src=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-time-settings.webp\" alt=\"FC1500 OTDR optical reflectometer time configuration interface\" class=\"wp-image-3709\" srcset=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-time-settings.webp 833w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-time-settings-300x179.webp 300w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-time-settings-768x458.webp 768w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-time-settings-18x12.webp 18w\" sizes=\"auto, (max-width: 833px) 100vw, 833px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">OTDR-Pulse width selection<br>Under automatic OTDR, when\u00a0<br>manually setting the measure<br>ment range, OTDR will auto<br>matically select the most\u00a0<br>suitable reference pulse width.\u00a0<br>In manual averaging mode, the\u00a0<br>measurement range and pulse\u00a0<br>width can be manually adjust<br>ed. The list on the right is for\u00a0<br>reference only:<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"747\" src=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-pulse-range-specifications-1024x747.webp\" alt=\"FC1500 OTDR pulse width test range specifications table\" class=\"wp-image-3710\" srcset=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-pulse-range-specifications-1024x747.webp 1024w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-pulse-range-specifications-300x219.webp 300w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-pulse-range-specifications-768x560.webp 768w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-pulse-range-specifications-16x12.webp 16w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-pulse-range-specifications.webp 1241w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Faults and Solutions<br>The description in the table\u00a0<br>on the right is for reference\u00a0<br>only. Please refer to the new\u00a0<br>instruction for detailed usage.\u00a0<br>In the process of using the\u00a0<br>instrument, if you have any\u00a0<br>questions, you can contact\u00a0<br>the instrument supplier.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"817\" src=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-troubleshooting-guide-1024x817.webp\" alt=\"FC1500 OTDR troubleshooting guide fault solutions\" class=\"wp-image-3711\" srcset=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-troubleshooting-guide-1024x817.webp 1024w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-troubleshooting-guide-300x239.webp 300w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-troubleshooting-guide-768x613.webp 768w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-troubleshooting-guide-15x12.webp 15w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/fc1500-otdr-troubleshooting-guide.webp 1232w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Instrument maintenance<br>Cleaning of connectors<br>\u00a0The optical output interface of this series OTDR is replaceable, and the end face must be kept clean during use. When\u00a0<br>the instrument fails to test a normal curve or the test results are inaccurate, the first consideration is to clean the connector.<br>When cleaning, please ensure that both OTDR and visible red light fault location functions are turned off. Unscrew the\u00a0<br>output interface and use a dedicated dust-free tissue or cotton swab dampened with alcohol to wipe the connection end\u00a0<br>face.<br>At the same time, please cover the dust cap after using the instrument and keep it dust-proof and clean.<br>Instrument screen cleaning<br>The display of this series of optical time domain reflectometer is a 4.3-inch TFT full view color LCD with a capacitive\u00a0<br>touch screen. When using, sharp objects should not be used to click on the LCD screen, as it may be damaged. When\u00a0<br>cleaning, a soft paper can be used to wipe and clean the LCD screen. Do not use organic solvents to wipe the LCD screen,\u00a0<br>otherwise it may cause damage to the LCD screen.<\/p>","protected":false},"excerpt":{"rendered":"<p>PREFACEThank you very much for purchasing and using this series of optical time domain reflectometers.\u00a0This manual mainly contains the common operation and maintenance information of the instrument, as well as the common troubleshooting guide and other information. In order to facilitate\u00a0your use, please read the contents of this manual carefully before operating the instrument, and\u00a0follow &#8230; <a title=\"Guide d&#039;utilisation du FC1500\" class=\"read-more\" href=\"https:\/\/firstfibertech.com\/fr\/blog\/fc1500-user-guide\/\" aria-label=\"En savoir plus sur FC1500 User Guide\">Lire la suite<\/a><\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[100],"tags":[],"class_list":["post-3676","post","type-post","status-publish","format-standard","hentry","category-otdr-fc1500"],"_links":{"self":[{"href":"https:\/\/firstfibertech.com\/fr\/wp-json\/wp\/v2\/posts\/3676","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/firstfibertech.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/firstfibertech.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/firstfibertech.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/firstfibertech.com\/fr\/wp-json\/wp\/v2\/comments?post=3676"}],"version-history":[{"count":2,"href":"https:\/\/firstfibertech.com\/fr\/wp-json\/wp\/v2\/posts\/3676\/revisions"}],"predecessor-version":[{"id":3865,"href":"https:\/\/firstfibertech.com\/fr\/wp-json\/wp\/v2\/posts\/3676\/revisions\/3865"}],"wp:attachment":[{"href":"https:\/\/firstfibertech.com\/fr\/wp-json\/wp\/v2\/media?parent=3676"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/firstfibertech.com\/fr\/wp-json\/wp\/v2\/categories?post=3676"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/firstfibertech.com\/fr\/wp-json\/wp\/v2\/tags?post=3676"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}