{"id":4038,"date":"2026-10-12T09:35:37","date_gmt":"2026-10-12T09:35:37","guid":{"rendered":"https:\/\/firstfibertech.com\/?p=4038"},"modified":"2026-10-28T10:58:43","modified_gmt":"2026-10-28T10:58:43","slug":"defis-lies-a-lutilisation-de-la-longueur-donde-de-1-650-nm-lors-des-tests-otdr-en-service-pour-les-reseaux-pon-10g-et-gpon-existants-coexistants","status":"publish","type":"post","link":"https:\/\/firstfibertech.com\/fr\/blog\/challenges-of-1650-nm-in-service-otdr-testing-for-co-existing-10g-pon-and-legacy-gpon-networks\/","title":{"rendered":"D\u00e9fis li\u00e9s aux tests OTDR \u00e0 1 650 nm en service pour les r\u00e9seaux 10G-PON et GPON traditionnels coexistants"},"content":{"rendered":"<h2 class=\"wp-block-heading\">R\u00e9sum\u00e9<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Le diagnostic des fibres en service est essentiel pour les op\u00e9rateurs qui d\u00e9ploient le 10G-PON parall\u00e8lement aux abonn\u00e9s GPON existants. Les mesures OTDR hors bande traditionnelles \u00e0 1 625 nm sont souvent alt\u00e9r\u00e9es par le bruit Raman et la diaphonie des filtres lorsque les fibres transportent des signaux descendants actifs \u00e0 1 490 nm, ce qui g\u00e9n\u00e8re des courbes bruit\u00e9es et des \u00e9v\u00e9nements de r\u00e9flexion parasites. Cet article examine les limites physiques des longueurs d\u2019onde de sondage \u00e0 1 625 nm au sein des r\u00e9seaux PON \u00e0 g\u00e9n\u00e9rations mixtes, analyse les compromis optiques fondamentaux li\u00e9s \u00e0 l\u2019adoption de la bande de 1 650 nm comme bande de test alternative, et r\u00e9sume les contraintes op\u00e9rationnelles pratiques observ\u00e9es lors d\u2019essais sur le terrain \u00e0 grande \u00e9chelle sur des r\u00e9seaux en service. Cette analyse fournit des orientations pour d\u00e9finir les exigences de test applicables aux d\u00e9ploiements NG-PON2 et aux futurs r\u00e9seaux d\u2019acc\u00e8s par fibre optique \u00e0 longueurs d\u2019onde multiples.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">1. Introduction<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Les infrastructures d\u2019acc\u00e8s par fibre optique prennent g\u00e9n\u00e9ralement en charge plusieurs normes PON sur une m\u00eame fibre physique. Lorsque les op\u00e9rateurs d\u00e9ploient le XGS-PON (10G-PON), les services GPON existants doivent rester actifs, ce qui signifie que la fibre transporte simultan\u00e9ment des signaux GPON en aval \u00e0 1 490 nm ainsi que de nouveaux canaux de longueur d\u2019onde 10G-PON. La localisation des d\u00e9fauts et la v\u00e9rification des liaisons doivent donc s'appuyer sur des longueurs d'onde de test hors bande qui n'interrompent pas le trafic en direct des abonn\u00e9s.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La bande de 1 625 nm est utilis\u00e9e depuis longtemps pour la maintenance sur site des r\u00e9seaux GPON. Cependant, lorsque cette longueur d\u2019onde de sonde partage la fibre avec un trafic aval \u00e0 haute puissance de 1 490 nm, deux m\u00e9canismes de d\u00e9gradation apparaissent : une fuite r\u00e9siduelle des longueurs d\u2019onde de service \u00e0 travers les ports du filtre WDM, et une diffusion Raman induite par le signal optique dans la bande. Ces deux ph\u00e9nom\u00e8nes g\u00e9n\u00e8rent des artefacts de mesure, notamment un bruit de trace \u00e9lev\u00e9 et des \u00e9v\u00e9nements fant\u00f4mes, qui r\u00e9duisent la fiabilit\u00e9 lors de la localisation des \u00e9pissures, des connecteurs et des ports de r\u00e9partiteurs passifs.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Afin d\u2019obtenir une meilleure s\u00e9paration spectrale par rapport \u00e0 toutes les bandes de signaux PON actives, certains concepteurs de r\u00e9seaux ont retenu la longueur d\u2019onde de 1 650 nm comme longueur d\u2019onde de test hors bande potentielle. \u00c0 1 650 nm, une isolation suffisante de la bande de garde est maintenue pour le trafic \u00e0 1 270 nm, 1 490 nm et 1 577 nm, tandis que la bande reste compatible avec les mesures effectu\u00e9es via des s\u00e9parateurs \u00e0 rapport \u00e9lev\u00e9 allant jusqu\u2019\u00e0 1:64. N\u00e9anmoins, le passage des tests \u00e0 1 650 nm entra\u00eene des pertes optiques intrins\u00e8ques qui doivent \u00eatre compens\u00e9es au niveau du mat\u00e9riel de test utilis\u00e9 sur le terrain.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Malgr\u00e9 le d\u00e9ploiement g\u00e9n\u00e9ralis\u00e9 de r\u00e9seaux GPON et 10G-PON coexistants, les directives officielles du secteur pr\u00e9cisant les longueurs d\u2019onde de test hors bande recommand\u00e9es pour les environnements hybrides restent incompl\u00e8tes. La plupart des sp\u00e9cifications de test des op\u00e9rateurs r\u00e9gionaux s'appuient encore par d\u00e9faut sur des proc\u00e9dures \u00e0 1 625 nm con\u00e7ues pour des r\u00e9seaux GPON de premi\u00e8re g\u00e9n\u00e9ration, sans tenir compte des seuils de bruit Raman caus\u00e9s par les canaux descendants \u00e0 haute puissance des r\u00e9seaux 10G-PON. Cela entra\u00eene une qualit\u00e9 de mesure sur le terrain in\u00e9gale dans les d\u00e9ploiements modernes d'acc\u00e8s par fibre optique.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"559\" src=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/10\/Figure-1-Wavelength-spectrum-overview-in-co-existing-PON-environments-1024x559.jpg\" alt=\"Figure 1 : Aper\u00e7u du spectre des longueurs d&#039;onde dans des environnements PON coexistants.\" class=\"wp-image-4040\" srcset=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/10\/Figure-1-Wavelength-spectrum-overview-in-co-existing-PON-environments-1024x559.jpg 1024w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/10\/Figure-1-Wavelength-spectrum-overview-in-co-existing-PON-environments-300x164.jpg 300w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/10\/Figure-1-Wavelength-spectrum-overview-in-co-existing-PON-environments-768x419.jpg 768w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/10\/Figure-1-Wavelength-spectrum-overview-in-co-existing-PON-environments-1536x838.jpg 1536w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/10\/Figure-1-Wavelength-spectrum-overview-in-co-existing-PON-environments-2048x1117.jpg 2048w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/10\/Figure-1-Wavelength-spectrum-overview-in-co-existing-PON-environments-18x10.jpg 18w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption translation-block\"><strong>Figure 1 : <\/strong>Aper\u00e7u du spectre de longueurs d'onde dans des environnements PON coexistants. <em>Le signal descendant XGS-PON haute puissance \u00e0 1 577 nm induit une bande de bruit Raman (zone ombr\u00e9e) qui d\u00e9grade consid\u00e9rablement les mesures OTDR \u00e0 1 625 nm, d\u00e9montrant ainsi la n\u00e9cessit\u00e9 de d\u00e9caler la longueur d'onde de test hors bande \u00e0 1 650 nm pour obtenir une isolation spectrale ad\u00e9quate.<\/em><\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">2. Compromis optiques fondamentaux pour la mise en \u0153uvre d'un OTDR de terrain \u00e0 1 650 nm<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">La principale limite des tests \u00e0 1 625 nm sur des liaisons 10G-PON en service provient de la diffusion Raman stimul\u00e9e (SRS). Le signal aval XGS-PON haute puissance \u00e0 1 577 nm agit comme un laser de pompage, g\u00e9n\u00e9rant un d\u00e9cal\u00e9 vers les basses fr\u00e9quences qui se situe pr\u00e9cis\u00e9ment dans la fen\u00eatre de test OTDR de 1 620 \u00e0 1 630 nm. Le bruit de fond qui en r\u00e9sulte augmente de mani\u00e8re non lin\u00e9aire avec la puissance d\u2019injection et la longueur de la fibre, produisant des artefacts de r\u00e9flexion al\u00e9atoires qui ne peuvent pas \u00eatre filtr\u00e9s par le seul moyennage num\u00e9rique conventionnel.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Par rapport \u00e0 1 625 nm, la longueur d'onde de 1 650 nm pr\u00e9sente un rendement de r\u00e9trodiffusion de Rayleigh plus faible et une att\u00e9nuation intrins\u00e8que de la fibre l\u00e9g\u00e8rement plus \u00e9lev\u00e9e. Ces deux effets r\u00e9duisent la plage dynamique atteignable, qui constitue le principal indicateur de performance pour tester les r\u00e9seaux de distribution PON \u00e0 base de s\u00e9parateurs limit\u00e9s par les pertes. Trois consid\u00e9rations fondamentales en mati\u00e8re de conception r\u00e9gissent la mise en place d\u2019une instrumentation de terrain viable :<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Source laser stable \u00e0 largeur de raie \u00e9troite : l'\u00e9metteur doit fournir une puissance de sonde exploitable tout en respectant les limites de s\u00e9curit\u00e9 oculaire de la classe 1. La stabilit\u00e9 de la puissance de sortie tout au long des cycles de temp\u00e9rature est indispensable pour garantir la r\u00e9p\u00e9tabilit\u00e9 des mesures dans des environnements ext\u00e9rieurs non contr\u00f4l\u00e9s.<\/li>\n\n\n\n<li>Front-end de r\u00e9cepteur optique \u00e0 faible bruit : des circuits de r\u00e9ception \u00e0 photodiodes \u00e0 avalanche et une amplification en plusieurs \u00e9tages sont n\u00e9cessaires pour r\u00e9cup\u00e9rer les signaux r\u00e9fl\u00e9chis faibles apr\u00e8s leur att\u00e9nuation par des s\u00e9parateurs PON mont\u00e9s en cascade. Le niveau de bruit de fond du r\u00e9cepteur doit \u00eatre ma\u00eetris\u00e9 afin de pr\u00e9server la r\u00e9solution spatiale pour les \u00e9v\u00e9nements r\u00e9fl\u00e9chissants tr\u00e8s rapproch\u00e9s.<\/li>\n\n\n\n<li>Traitement num\u00e9rique du signal : les algorithmes de suppression du bruit et la r\u00e9duction des zones mortes sont essentiels pour les d\u00e9ploiements dans les immeubles collectifs, o\u00f9 de nombreux connecteurs et \u00e9pissures sont pr\u00e9sents sur une courte longueur de fibre.<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\">Lorsque ces contraintes sont prises en compte au niveau du mat\u00e9riel et du micrologiciel, une plateforme OTDR \u00e0 1 650 nm peut offrir une plage dynamique sup\u00e9rieure \u00e0 37 dB et une zone morte inf\u00e9rieure \u00e0 1 m, ce qui la rend adapt\u00e9e \u00e0 la cartographie des d\u00e9fauts dans les architectures de distribution 10G-PON classiques.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"572\" src=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/10\/In-service-1625-nm-OTDR-trace-measured-on-an-active-10G-PON-link.jpg\" alt=\"Courbe OTDR \u00e0 1 625 nm mesur\u00e9e en service sur une liaison 10G-PON active.\" class=\"wp-image-4043\" srcset=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/10\/In-service-1625-nm-OTDR-trace-measured-on-an-active-10G-PON-link.jpg 1024w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/10\/In-service-1625-nm-OTDR-trace-measured-on-an-active-10G-PON-link-300x168.jpg 300w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/10\/In-service-1625-nm-OTDR-trace-measured-on-an-active-10G-PON-link-768x429.jpg 768w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/10\/In-service-1625-nm-OTDR-trace-measured-on-an-active-10G-PON-link-18x10.jpg 18w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\"><strong>Figure 2 :<\/strong> Courbe OTDR \u00e0 1 625 nm mesur\u00e9e en service sur une liaison 10G-PON active. La mesure est fortement d\u00e9grad\u00e9e par la diffusion Raman stimul\u00e9e induite par le signal aval \u00e0 haute puissance de 1 577 nm, ce qui entra\u00eene une \u00e9l\u00e9vation significative du bruit de fond et l'apparition d'\u00e9v\u00e9nements fant\u00f4mes parasites.<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"572\" src=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/10\/In-service-1650-nm-OTDR-trace-measured-on-the-same-active-10G-PON-link.jpg\" alt=\"Courbe OTDR \u00e0 1 650 nm mesur\u00e9e en service sur la m\u00eame liaison 10G-PON active\" class=\"wp-image-4044\" srcset=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/10\/In-service-1650-nm-OTDR-trace-measured-on-the-same-active-10G-PON-link.jpg 1024w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/10\/In-service-1650-nm-OTDR-trace-measured-on-the-same-active-10G-PON-link-300x168.jpg 300w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/10\/In-service-1650-nm-OTDR-trace-measured-on-the-same-active-10G-PON-link-768x429.jpg 768w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/10\/In-service-1650-nm-OTDR-trace-measured-on-the-same-active-10G-PON-link-18x10.jpg 18w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\"><strong>Figure 3 :<\/strong> Courbe OTDR \u00e0 1 650 nm mesur\u00e9e en service sur la m\u00eame liaison 10G-PON active. Gr\u00e2ce \u00e0 une isolation spectrale ad\u00e9quate par rapport \u00e0 la bande de bruit Raman, la longueur d'onde de la sonde \u00e0 1 650 nm permet de conserver une ligne de base propre, ce qui facilite la localisation pr\u00e9cise des composants optiques passifs et des d\u00e9fauts potentiels.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">3. Contraintes op\u00e9rationnelles observ\u00e9es lors des essais sur r\u00e9seau r\u00e9el<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Les performances en laboratoire ne suffisent pas \u00e0 elles seules \u00e0 garantir l'ad\u00e9quation \u00e0 des flux de travail sur le terrain. Des essais men\u00e9s dans des environnements PON en service, en milieu urbain, en p\u00e9riph\u00e9rie et dans des immeubles collectifs, ont mis en \u00e9vidence deux limites pratiques communes aux instruments de test destin\u00e9s aux installations ext\u00e9rieures, ind\u00e9pendamment de l'architecture optique sous-jacente.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Tout d'abord, les \u00e9crans classiques pr\u00e9sentent un faible contraste lorsqu'ils sont expos\u00e9s directement au soleil. Pour les techniciens intervenant sur les armoires de rue et les points d'\u00e9pissure a\u00e9riens, la lisibilit\u00e9 r\u00e9duite des trac\u00e9s ralentit le diagnostic des pannes. Tout instrument de terrain destin\u00e9 \u00e0 ce type d'utilisation doit privil\u00e9gier les caract\u00e9ristiques d'affichage lisibles en plein soleil.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">D'autre part, les programmes de mise en service et de maintenance des r\u00e9seaux PON \u00e0 haute densit\u00e9 exigent des techniciens qu'ils \u00e9valuent un grand nombre de liaisons fibre optique par service. Le fait de devoir positionner manuellement le curseur \u00e0 plusieurs reprises pour extraire des param\u00e8tres de base, tels que la longueur de la fibre et la perte totale, g\u00e9n\u00e8re une charge de travail inutile. La d\u00e9tection automatis\u00e9e des \u00e9v\u00e9nements et la g\u00e9n\u00e9ration automatis\u00e9e de rapports sur les param\u00e8tres peuvent rationaliser ces workflows de test \u00e0 haut d\u00e9bit.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Dans le cadre de l'essai, les mesures \u00e0 1 650 nm ont \u00e9t\u00e9 r\u00e9alis\u00e9es sans perturber les services PON actifs co-localis\u00e9s, et l'architecture de test \u00e9tait compatible avec les interfaces centralis\u00e9es de surveillance automatis\u00e9e des fibres.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">4. Discussion et perspectives<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u00c0 mesure que les d\u00e9ploiements NG-PON2 et 25G-PON se g\u00e9n\u00e9ralisent, la coexistence de plusieurs longueurs d\u2019onde de service sur une fibre partag\u00e9e deviendra la norme. Le choix des bandes de test hors bande doit \u00eatre \u00e9valu\u00e9 par rapport \u00e0 l\u2019ensemble complet des canaux actifs afin de pr\u00e9server des bandes de garde spectrales ad\u00e9quates.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La bande de 1 650 nm offre des avantages \u00e9vidents en mati\u00e8re d\u2019isolation pour les r\u00e9seaux PON mixtes, mais elle ne constitue pas pour autant un substitut universel \u00e0 la bande de 1 625 nm. Une att\u00e9nuation plus \u00e9lev\u00e9e de la fibre limite la port\u00e9e maximale sur les longues port\u00e9es d\u2019alimentation, et la disponibilit\u00e9 des composants, ainsi que le co\u00fbt du syst\u00e8me, restent des facteurs limitants concrets pour certains op\u00e9rateurs. Les concepteurs d\u2019instruments doivent trouver un \u00e9quilibre entre les performances optiques brutes et les exigences d\u2019utilisabilit\u00e9 sur le terrain, notamment la visibilit\u00e9 de l\u2019affichage, l\u2019analyse automatis\u00e9e et la compatibilit\u00e9 avec les plateformes de surveillance.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Dans des conditions r\u00e9elles sur le terrain, les courbes OTDR \u00e0 1 625 nm sur des fibres 10G-PON actives pr\u00e9sentent g\u00e9n\u00e9ralement une \u00e9l\u00e9vation du bruit de fond de 6 dB \u00e0 12 dB par rapport aux tests effectu\u00e9s sur des fibres inactives. Cette marge de bruit est suffisante pour masquer les \u00e9pissures \u00e0 faible perte et les faibles r\u00e9flexions au niveau des connecteurs, qui sont pourtant essentielles pour la maintenance pr\u00e9ventive. En revanche, le d\u00e9calage \u00e0 1 650 nm offre une isolation spectrale d\u2019environ 25 nm par rapport \u00e0 la bande de bruit Raman, \u00e9liminant ainsi la majeure partie de la d\u00e9gradation des mesures en service.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Les r\u00e9sultats op\u00e9rationnels issus des essais en conditions r\u00e9elles du r\u00e9seau 10G-PON montrent que la s\u00e9lection de la longueur d'onde ne constitue qu'un aspect parmi d'autres du cahier des charges des tests. L'utilit\u00e9 pratique d\u00e9pend tout autant de la prise en compte des contraintes li\u00e9es aux processus de travail sur le terrain, qui ne sont souvent pas prises en compte lors de la caract\u00e9risation des composants en laboratoire. Ces consid\u00e9rations peuvent servir de base \u00e0 la d\u00e9finition des exigences mat\u00e9rielles pour les syst\u00e8mes de test des r\u00e9seaux d'acc\u00e8s de nouvelle g\u00e9n\u00e9ration.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u00c0 mesure que les syst\u00e8mes NG-PON2 et 25G-PON seront d\u00e9ploy\u00e9s \u00e0 l'\u00e9chelle commerciale, la coexistence des longueurs d'onde qui se chevauchent deviendra encore plus complexe. Les crit\u00e8res de s\u00e9lection des longueurs d'onde de test pr\u00e9sent\u00e9s dans cet article peuvent faciliter la mise \u00e0 jour des proc\u00e9dures op\u00e9rationnelles standard des op\u00e9rateurs et contribuer \u00e0 la mise en place de cadres de validation sur le terrain plus solides pour les r\u00e9seaux d'acc\u00e8s par fibre optique multibandes de nouvelle g\u00e9n\u00e9ration.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">5. Mod\u00e8les d'OTDR \u00e0 1 650 nm de FirstFiber Technologies<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Mod\u00e8le<\/th><th>Longueur d&#039;onde<\/th><th>Plage dynamique<\/th><\/tr><\/thead><tbody><tr><td><a href=\"https:\/\/firstfibertech.com\/fr\/produit\/otdr-max-8000\/\" data-type=\"ff_products\" data-id=\"469\">8000MAX-T3<\/a><\/td><td>1310\/1550\/1650 nm<\/td><td>35\/33\/32 dB<\/td><\/tr><tr><td><a href=\"https:\/\/firstfibertech.com\/fr\/produit\/otdr-max-8000\/\" data-type=\"ff_products\" data-id=\"469\">8000MAX-10G2<\/a><\/td><td>1310\/1550\/1270\/1577\/1650nm<\/td><td>37\/35\/35\/35\/35dB<\/td><\/tr><tr><td><a href=\"https:\/\/firstfibertech.com\/fr\/produit\/980exp-12-en-1-otdr\/\" data-type=\"ff_products\" data-id=\"369\">980EXP-B32<\/a><\/td><td>1650 nm<\/td><td>32 dB<\/td><\/tr><tr><td><a href=\"https:\/\/firstfibertech.com\/fr\/produit\/ff-990pro-otdr\/\" data-type=\"ff_products\" data-id=\"516\">FF-990PRO-PS2<\/a><\/td><td>1650 nm<\/td><td>38 dB<\/td><\/tr><tr><td><a href=\"https:\/\/firstfibertech.com\/fr\/produit\/ff-990pro-otdr\/\" data-type=\"ff_products\" data-id=\"516\">FF-990PRO-PT4<\/a><\/td><td>1310\/1550\/1650 nm<\/td><td>38\/36\/36 dB<\/td><\/tr><tr><td><a href=\"https:\/\/firstfibertech.com\/fr\/produit\/mini-otdr-980rtc-pratique\/\" data-type=\"ff_products\" data-id=\"480\">980RTC-B26<\/a><\/td><td>1650 nm<\/td><td>26 dB<\/td><\/tr><tr><td><a href=\"https:\/\/firstfibertech.com\/fr\/produit\/mini-otdr-980rtc-pratique\/\" data-type=\"ff_products\" data-id=\"480\">980RTC-T3<\/a><\/td><td>1310\/1550\/1650 nm<\/td><td>24\/22\/22 dB<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Consulter <a href=\"https:\/\/firstfibertech.com\/fr\/produits\/test-et-mesure\/otdrs\/\" data-type=\"ff_product_cat\" data-id=\"6\">tous les mod\u00e8les<\/a>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>R\u00e9sum\u00e9 : Le diagnostic des fibres en service est essentiel pour les op\u00e9rateurs qui d\u00e9ploient le r\u00e9seau 10G-PON parall\u00e8lement aux abonn\u00e9s GPON existants. Les mesures OTDR hors bande traditionnelles \u00e0 1 625 nm sont souvent alt\u00e9r\u00e9es par le bruit Raman et la diaphonie des filtres lorsque les fibres transportent des signaux descendants actifs \u00e0 1 490 nm, ce qui g\u00e9n\u00e8re des courbes bruit\u00e9es et des \u00e9v\u00e9nements de r\u00e9flexion parasites. Cet article examine les limites physiques des longueurs d\u2019onde de sondage \u00e0 1 625 nm dans les r\u00e9seaux \u00e0 g\u00e9n\u00e9rations mixtes\u2026 <a title=\"D\u00e9fis li\u00e9s aux tests OTDR \u00e0 1 650 nm en service pour les r\u00e9seaux 10G-PON et GPON traditionnels coexistants\" class=\"read-more\" href=\"https:\/\/firstfibertech.com\/fr\/blog\/challenges-of-1650-nm-in-service-otdr-testing-for-co-existing-10g-pon-and-legacy-gpon-networks\/\" aria-label=\"En savoir plus sur Challenges of 1650\u202fnm in\u2011service OTDR testing for co\u2011existing 10G\u2011PON and legacy GPON networks\">Lire la suite<\/a><\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[98],"tags":[],"class_list":["post-4038","post","type-post","status-publish","format-standard","hentry","category-otdr-wiki"],"_links":{"self":[{"href":"https:\/\/firstfibertech.com\/fr\/wp-json\/wp\/v2\/posts\/4038","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/firstfibertech.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/firstfibertech.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/firstfibertech.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/firstfibertech.com\/fr\/wp-json\/wp\/v2\/comments?post=4038"}],"version-history":[{"count":3,"href":"https:\/\/firstfibertech.com\/fr\/wp-json\/wp\/v2\/posts\/4038\/revisions"}],"predecessor-version":[{"id":4046,"href":"https:\/\/firstfibertech.com\/fr\/wp-json\/wp\/v2\/posts\/4038\/revisions\/4046"}],"wp:attachment":[{"href":"https:\/\/firstfibertech.com\/fr\/wp-json\/wp\/v2\/media?parent=4038"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/firstfibertech.com\/fr\/wp-json\/wp\/v2\/categories?post=4038"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/firstfibertech.com\/fr\/wp-json\/wp\/v2\/tags?post=4038"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}