{"id":1077,"date":"2026-08-04T06:38:14","date_gmt":"2026-08-04T06:38:14","guid":{"rendered":"https:\/\/firstfibertech.com\/?post_type=ff_products&#038;p=1077"},"modified":"2026-09-08T02:22:33","modified_gmt":"2026-09-08T02:22:33","slug":"zamkniecie-swiatlowodowe-ff-ftb16q-do-terminala-dostepowego-swiatlowodowego","status":"publish","type":"ff_products","link":"https:\/\/firstfibertech.com\/pl\/product\/ff-ftb16q-fiber-drop-closure-for-fiber-access-terminal\/","title":{"rendered":"FF-FTB16Q Z\u0142\u0105cze \u015bwiat\u0142owodowe do terminala dost\u0119powego \u015bwiat\u0142owodowego"},"content":{"rendered":"<h2 class=\"wp-block-heading\">Opis<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Mufa \u015bwiat\u0142owodowa FF-FTB16Q do \u015bwiat\u0142owodowego terminala dost\u0119powego to \u017celowa mufa do spawania i krosowania \u015bwiat\u0142owod\u00f3w, przeznaczona do zastosowa\u0144 w \u015bwiat\u0142owodowych punktach dost\u0119powych w sieciach telekomunikacyjnych poza zak\u0142adem. Mufa FF-FTB16Q do \u015bwiat\u0142owodowego terminala dost\u0119powego posiada 3 porty kablowe g\u0142\u00f3wne i 16 port\u00f3w kablowych odga\u0142\u0119\u017anych. P\u0119tla z 6-metrowymi lu\u017anymi tubami pozwala na jednoczesne przechodzenie dw\u00f3ch kabli g\u0142\u00f3wnych. Mufa mie\u015bci do 12 spaw\u00f3w zgrzewanych (lub 4 spaw\u00f3w mechanicznych), dwa splittery PLC i 16 adapter\u00f3w SC. Uszczelnienie jest realizowane dzi\u0119ki wbudowanej technologii \u017celowej, co zapewnia wyj\u0105tkowo wygodne ponowne wprowadzanie i uszczelnianie.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Cechy:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Uszczelnienie \u017celowe zapewniaj\u0105ce doskona\u0142e w\u0142a\u015bciwo\u015bci uszczelniaj\u0105ce i umo\u017cliwiaj\u0105ce ponowne uszczelnianie<\/li>\n\n\n\n<li>Wysokiej jako\u015bci materia\u0142 in\u017cynieryjny z PP o dobrej wytrzyma\u0142o\u015bci mechanicznej, solidno\u015bci i trwa\u0142o\u015bci<\/li>\n\n\n\n<li>U\u0142o\u017cona w stos tacka na z\u0142\u0105cza, \u0142atwa do otwierania, wyjmowania, instalacji i konserwacji<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Normy:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>UL 94, Test palno\u015bci tworzyw sztucznych stosowanych w cz\u0119\u015bciach urz\u0105dze\u0144 i sprz\u0119t\u00f3w AGD<\/li>\n\n\n\n<li>Skrzynka rozdzielcza \u015bwiat\u0142owodu YD\/T2150-2010<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Specyfikacja:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td>Maksymalna pojemno\u015b\u0107<\/td><td>16 w\u0142\u00f3kien<\/td><\/tr><tr><td>Maksymalna \u015brednica kabla wlotowego<\/td><td>20 mm<\/td><\/tr><tr><td>Numer kabla wlotowego<\/td><td>3 sztuki<\/td><\/tr><tr><td>\u015arednica kabla odga\u0142\u0119\u017anego<\/td><td>Kabel opadowy 2\u00d73m<\/td><\/tr><tr><td>Numer kabla wyj\u015bciowego<\/td><td>16 szt.<\/td><\/tr><tr><td>Stopie\u0144 ochrony<\/td><td>IP68<\/td><\/tr><tr><td>Metoda instalacji<\/td><td>Monta\u017c na \u015bcianie i na s\u0142upie (pier\u015bcie\u0144 do s\u0142upa jest opcjonalny)<\/td><\/tr><tr><td>\u015arodowisko pracy<\/td><td>Na zewn\u0105trz i wewn\u0105trz<\/td><\/tr><tr><td>Wymiar<\/td><td>300(wys.)*210(szer.)*105(g\u0142.)mm<\/td><\/tr><tr><td>Temperatura pracy<\/td><td>-40\u00b0C~+65\u00b0C<\/td><\/tr><tr><td>Temperatura przechowywania<\/td><td>-40\u00b0C~+70\u00b0C<\/td><\/tr><tr><td>Wilgotno\u015b\u0107 wzgl\u0119dna<\/td><td>0%~85% (+30\u00b0C)<\/td><\/tr><tr><td>Ci\u015bnienie powietrza<\/td><td>70~106KPa<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td>Model<\/td><td>Rozmiar<br>A*B*C (mm)<\/td><td>Maksymalna pojemno\u015b\u0107<\/td><td>Rozmiar instalacji wie\u017cy wiertniczej<br>D*E*F(mm)<\/td><td>najwi\u0119ksza \u015brednica kabla (mm)<\/td><\/tr><tr><td>FF-FTB16Q<\/td><td>300*210*105<\/td><td>16<\/td><td>190*227*142<\/td><td>20 mm<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"442\" src=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/ff-ftb16q-fiber-closure-dimensions-1024x442.webp\" alt=\"Wymiary rysunku technicznego skrzynki przy\u0142\u0105czeniowej \u015bwiat\u0142owodowej FF-FTB16Q\" class=\"wp-image-1078\" srcset=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/ff-ftb16q-fiber-closure-dimensions-1024x442.webp 1024w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/ff-ftb16q-fiber-closure-dimensions-300x129.webp 300w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/ff-ftb16q-fiber-closure-dimensions-768x331.webp 768w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/ff-ftb16q-fiber-closure-dimensions-18x8.webp 18w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/ff-ftb16q-fiber-closure-dimensions.webp 1133w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"315\" src=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/ff-ftb16q-fiber-closure-diagram-1024x315.webp\" alt=\"Schemat okablowania skrzynki przy\u0142\u0105czeniowej \u015bwiat\u0142owodu FF-FTB16Q\" class=\"wp-image-1079\" srcset=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/ff-ftb16q-fiber-closure-diagram-1024x315.webp 1024w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/ff-ftb16q-fiber-closure-diagram-300x92.webp 300w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/ff-ftb16q-fiber-closure-diagram-768x236.webp 768w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/ff-ftb16q-fiber-closure-diagram-18x6.webp 18w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/ff-ftb16q-fiber-closure-diagram.webp 1162w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"528\" src=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/ff-ftb16q-fiber-closure-wall-pole-1024x528.webp\" alt=\"Z\u0142\u0105cze \u015bwiat\u0142owodowe FF-FTB16Q do monta\u017cu na \u015bcianie lub s\u0142upie\" class=\"wp-image-1080\" srcset=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/ff-ftb16q-fiber-closure-wall-pole-1024x528.webp 1024w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/ff-ftb16q-fiber-closure-wall-pole-300x155.webp 300w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/ff-ftb16q-fiber-closure-wall-pole-768x396.webp 768w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/ff-ftb16q-fiber-closure-wall-pole-18x9.webp 18w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/ff-ftb16q-fiber-closure-wall-pole.webp 1083w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"800\" src=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/firstfiber-ff-ftb16q-drop-closure-AZxS.webp\" alt=\"FirstFiber FF-FTB16Q \u2013 skrzynka przy\u0142\u0105czeniowa \u015bwiat\u0142owodowa\" class=\"wp-image-1081\" srcset=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/firstfiber-ff-ftb16q-drop-closure-AZxS.webp 800w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/firstfiber-ff-ftb16q-drop-closure-AZxS-300x300.webp 300w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/firstfiber-ff-ftb16q-drop-closure-AZxS-150x150.webp 150w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/firstfiber-ff-ftb16q-drop-closure-AZxS-768x768.webp 768w, https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/08\/firstfiber-ff-ftb16q-drop-closure-AZxS-12x12.webp 12w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Cz\u0119sto zadawane pytania<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Pytanie 1: Jaka jest g\u0142\u00f3wna konstrukcja i przeznaczenie modelu FF-FTB16Q?<\/strong> <\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A:<\/strong> FF-FTB16Q to zamkni\u0119ta, uszczelniona \u017celem skrzynka do \u0142\u0105czenia i rozga\u0142\u0119ziania \u015bwiat\u0142owod\u00f3w typu \u201ebutt\u201d, zaprojektowana z my\u015bl\u0105 o punktach dost\u0119pu do \u015bwiat\u0142owod\u00f3w w zewn\u0119trznych sieciach telekomunikacyjnych.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Pytanie 2: Jaka jest przepustowo\u015b\u0107 portu kablowego i pojemno\u015b\u0107 pami\u0119ci p\u0119tli?<\/strong> <\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A:<\/strong> Posiada 3 g\u0142\u00f3wne porty kablowe (maksymalna \u015brednica kabla wynosi 20 mm) oraz 16 port\u00f3w dla kabli odga\u0142\u0119\u017anych. Wyposa\u017cony jest w 6-metrow\u0105 p\u0119tl\u0119 do przechowywania kabli w lu\u017anej rurce, umo\u017cliwiaj\u0105c\u0105 jednoczesne przeprowadzenie przez ni\u0105 dw\u00f3ch kabli g\u0142\u00f3wnych.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Pytanie 3: Jakie elementy wewn\u0119trzne mie\u015bci ta obudowa?<\/strong> <\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A:<\/strong> W obudowie zmie\u015bci si\u0119 maksymalnie 12 po\u0142\u0105cze\u0144 fuzyjnych (lub 4 po\u0142\u0105czenia mechaniczne), dwa rozga\u0142\u0119\u017aniki PLC oraz 16 adapter\u00f3w SC.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Pytanie 4: Jakie s\u0105 stopnie ochrony, spos\u00f3b uszczelnienia i materia\u0142 konstrukcyjny?<\/strong> <\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A:<\/strong> Wykonany z polipropylenu (PP) o wysokiej wytrzyma\u0142o\u015bci, zgodnego z normami palno\u015bci UL 94, charakteryzuje si\u0119 stopniem ochrony IP68. Wbudowana technologia uszczelnienia \u017celowego umo\u017cliwia wygodne ponowne otwarcie i ponowne uszczelnienie.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Pytanie 5: Jakie s\u0105 wymiary, mo\u017cliwo\u015bci monta\u017cu i warunki pracy?<\/strong> <\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A:<\/strong> Urz\u0105dzenie o wymiarach 300 x 210 x 105 mm mo\u017cna zamontowa\u0107 zar\u00f3wno na \u015bcianie, jak i na s\u0142upie, zar\u00f3wno wewn\u0105trz, jak i na zewn\u0105trz budynk\u00f3w, a jego temperatura pracy wynosi od -40\u00b0C do +65\u00b0C.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Pytanie 6: Jakie opcje adapter\u00f3w i kabli przy\u0142\u0105czeniowych mo\u017cna skonfigurowa\u0107?<\/strong> <\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A:<\/strong> Dost\u0119pne konfiguracje obejmuj\u0105 16 sztuk adapter\u00f3w SC\/APC lub SC\/UPC w po\u0142\u0105czeniu z 16 pigtailami SC\/APC lub SC\/UPC, a tak\u017ce mo\u017cliwo\u015b\u0107 z\u0142o\u017cenia zam\u00f3wienia bez adapter\u00f3w i pigtaili.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Pytanie 7: Jaka jest cena referencyjna modelu FF-FTB16Q?<\/strong> <\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A:<\/strong> Podstawowa cena referencyjna za skrzynk\u0119 przy\u0142\u0105czeniow\u0105 \u015bwiat\u0142owodu FF-FTB16Q wynosi $35 USD.<\/p>","protected":false},"excerpt":{"rendered":"<p>Opis: FF-FTB16Q \u2013 skrzynka przy\u0142\u0105czeniowa \u015bwiat\u0142owodowa do terminala dost\u0119powego to skrzynka do \u0142\u0105czenia i rozga\u0142\u0119ziania \u015bwiat\u0142owod\u00f3w typu czo\u0142owego, uszczelniona \u017celem, przeznaczona do zastosowa\u0144 w punktach dost\u0119powych sieci telekomunikacyjnej na zewn\u0105trz budynk\u00f3w. FF-FTB16Q \u2013 skrzynka przy\u0142\u0105czeniowa \u015bwiat\u0142owodowa do terminala dost\u0119powego posiada 3 g\u0142\u00f3wne porty kablowe i 16 port\u00f3w kabli odga\u0142\u0119\u017anych. Miejsce na 6 m lu\u017anego kabla p\u0119tlowego \u2026 <a title=\"FF-FTB16Q Z\u0142\u0105cze \u015bwiat\u0142owodowe do terminala dost\u0119powego \u015bwiat\u0142owodowego\" class=\"read-more\" href=\"https:\/\/firstfibertech.com\/pl\/product\/ff-ftb16q-fiber-drop-closure-for-fiber-access-terminal\/\" aria-label=\"Dowiedz si\u0119 wi\u0119cej o FF-FTB16Q Fiber Drop Closure for Fiber Access Terminal\">Dowiedz si\u0119 wi\u0119cej<\/a><\/p>","protected":false},"featured_media":2726,"template":"","ff_product_cat":[32,29,30],"class_list":["post-1077","ff_products","type-ff_products","status-publish","has-post-thumbnail","hentry","ff_product_cat-16-cores-fiber-box","ff_product_cat-fiber-cable-management","ff_product_cat-fiber-terminal-box"],"_links":{"self":[{"href":"https:\/\/firstfibertech.com\/pl\/wp-json\/wp\/v2\/ff_products\/1077","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/firstfibertech.com\/pl\/wp-json\/wp\/v2\/ff_products"}],"about":[{"href":"https:\/\/firstfibertech.com\/pl\/wp-json\/wp\/v2\/types\/ff_products"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/firstfibertech.com\/pl\/wp-json\/wp\/v2\/media\/2726"}],"wp:attachment":[{"href":"https:\/\/firstfibertech.com\/pl\/wp-json\/wp\/v2\/media?parent=1077"}],"wp:term":[{"taxonomy":"ff_product_cat","embeddable":true,"href":"https:\/\/firstfibertech.com\/pl\/wp-json\/wp\/v2\/ff_product_cat?post=1077"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}