{"id":2523,"date":"2026-08-12T07:40:26","date_gmt":"2026-08-12T07:40:26","guid":{"rendered":"https:\/\/firstfibertech.com\/?post_type=ff_products&#038;p=2523"},"modified":"2026-09-01T06:59:42","modified_gmt":"2026-09-01T06:59:42","slug":"rama-szafy-sieciowej-i-serwerowej-serii-f3","status":"publish","type":"ff_products","link":"https:\/\/firstfibertech.com\/pl\/product\/f3-series-network-and-server-cabinet-frame\/","title":{"rendered":"Rama szafy sieciowej i serwerowej serii F3"},"content":{"rendered":"<h2 class=\"wp-block-heading\">Opis<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Rama szafy sieciowo-serwerowej serii F3 z przednimi i tylnymi drzwiami wyposa\u017conymi w sze\u015bciok\u0105tn\u0105 siatkow\u0105 p\u0142yt\u0119 wentylacyjn\u0105 o du\u017cej g\u0119sto\u015bci<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Standardy<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Zgodno\u015b\u0107 z normami ANSI\/EIA RS-310-D, IEC 297-2, DIN 41494; cz\u0119\u015b\u0107 1, DIN 41494; cz\u0119\u015b\u0107 7 oraz norm\u0105 ETSI.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Funkcje<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Wykwintny projekt charakteryzuj\u0105cy si\u0119 precyzyjnymi wymiarami i kunsztownym wykonaniem;<\/li>\n\n\n\n<li>Przednie i tylne drzwi z wentylowanymi p\u0142ytami o wysokiej g\u0119sto\u015bci o sze\u015bciok\u0105tnej strukturze siatkowej;<\/li>\n\n\n\n<li>W ofercie dost\u0119pne s\u0105 jednocze\u015bnie regulowane n\u00f3\u017cki i wytrzyma\u0142e k\u00f3\u0142ka;<\/li>\n\n\n\n<li>Kilka zamykanych przej\u015b\u0107 kablowych w g\u00f3rnej pokrywie i dolnym panelu o regulowanych rozmiarach;<\/li>\n\n\n\n<li>Zdejmowane panele boczne, \u0142atwe w monta\u017cu i konserwacji;<\/li>\n\n\n\n<li>W stanie spakowanym zajmuje oko\u0142o 1\/2\u20132\/3 pierwotnej obj\u0119to\u015bci po z\u0142o\u017ceniu.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">G\u0142\u00f3wny materia\u0142<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Stal walcowana na zimno SPCC;<\/li>\n\n\n\n<li>Grubo\u015b\u0107: profil monta\u017cowy 2,0 mm, k\u0105townik monta\u017cowy 1,5 mm, pozosta\u0142e elementy 1,2 mm.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Wyko\u0144czenie powierzchni<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>odt\u0142uszczanie, trawienie, fosforanowanie, malowanie proszkowe;<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Stopie\u0144 ochrony<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>IP20<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\u0141adowno\u015b\u0107<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Obci\u0105\u017cenie statyczne: 800 kg<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td>Pojemno\u015b\u0107 (U)<\/td><td>Szeroko\u015b\u0107<br>(mm)<\/td><td>G\u0142\u0119boko\u015b\u0107<br>(mm)<\/td><td>Wysoko\u015b\u0107 (mm)<\/td><td>Wymiary opakowania<br>W*D*H<\/td><td>Obj\u0119to\u015b\u0107<br>(CBM)<\/td><td><\/td><\/tr><tr><td rowspan=\"3\">18<\/td><td rowspan=\"3\">600<\/td><td>600<\/td><td rowspan=\"3\">988<\/td><td>670*670*1028<\/td><td>0.5992<\/td><td>1 szt. taca<br>1 szt. PDU 10 A<br>2 wentylatory<\/td><\/tr><tr><td>800<\/td><td>670*870*1028<\/td><td>0.5992<\/td><td>1 szt. taca<br>1 szt. PDU 10 A<br>4 wentylatory<\/td><\/tr><tr><td>1000<\/td><td>670*1070*1028<\/td><td>0.7370<\/td><td>1 szt. taca<br>1 szt. PDU 10 A<br>4 wentylatory<\/td><\/tr><tr><td rowspan=\"3\">22<\/td><td rowspan=\"3\">600<\/td><td>600<\/td><td rowspan=\"3\">1166<\/td><td>670*670*1196<\/td><td>0.5369<\/td><td>1 szt. taca<br>1 szt. PDU 10 A<br>2 wentylatory<\/td><\/tr><tr><td>800<\/td><td>670*870*1196<\/td><td>0.6971<\/td><td>1 szt. taca<br>1 szt. PDU 10 A<br>4 wentylatory<\/td><\/tr><tr><td>1000<\/td><td>670*1070*1196<\/td><td>0.8574<\/td><td>1 szt. taca<br>1 szt. PDU 10 A<br>4 wentylatory<\/td><\/tr><tr><td rowspan=\"3\">27<\/td><td rowspan=\"3\">600<\/td><td>600<\/td><td rowspan=\"3\">1388<\/td><td>670*670*1418<\/td><td>0.6460<\/td><td>1 szt. taca<br>1 szt. PDU 10 A<br>2 wentylatory<\/td><\/tr><tr><td>800<\/td><td>670*870*1418<\/td><td>0.8266<\/td><td>1 szt. taca<br>1 szt. PDU 10 A<br>4 wentylatory<\/td><\/tr><tr><td>1000<\/td><td>670*1070*1418<\/td><td>1.0166<\/td><td>1 szt. taca<br>1 szt. PDU 10 A<br>4 wentylatory<\/td><\/tr><tr><td rowspan=\"3\">32<\/td><td rowspan=\"3\">600<\/td><td>600<\/td><td rowspan=\"3\">1610<\/td><td>670*670*1640<\/td><td>0.7362<\/td><td>1 szt. taca<br>1 szt. PDU 10 A<br>2 wentylatory<\/td><\/tr><tr><td>800<\/td><td>670*870*1640<\/td><td>0.9560<\/td><td>1 szt. taca<br>1 szt. PDU 10 A<br>4 wentylatory<\/td><\/tr><tr><td>1000<\/td><td>670*1070*1640<\/td><td>1.1757<\/td><td>1 szt. taca<br>1 szt. PDU 10 A<br>4 wentylatory<\/td><\/tr><tr><td rowspan=\"4\">37<\/td><td rowspan=\"4\">600<\/td><td>600<\/td><td rowspan=\"4\">1833<\/td><td>670*670*1863<\/td><td>0.8363<\/td><td>3 tacki<br>1 szt. PDU 10 A<br>2 wentylatory<\/td><\/tr><tr><td>800<\/td><td>670*870*1863<\/td><td>1.0859<\/td><td>3 tacki<br>1 szt. PDU 10 A<br>4 wentylatory<\/td><\/tr><tr><td>1000<\/td><td>670*1070*1863<\/td><td>1.3356<\/td><td>3 tacki<br>1 szt. PDU 10 A<br>4 wentylatory<\/td><\/tr><tr><td>1200<\/td><td>670*1270*1863<\/td><td>1.5852<\/td><td>3 tacki<br>1 szt. PDU 10 A<br>4 wentylatory<\/td><\/tr><tr><td rowspan=\"8\">42<\/td><td rowspan=\"4\">600<\/td><td>600<\/td><td rowspan=\"8\">2055<\/td><td>670*670*2085<\/td><td>0.9360<\/td><td>3 tacki<br>1 szt. PDU 10 A<br>2 wentylatory<\/td><\/tr><tr><td>800<\/td><td>670*870*2085<\/td><td>1.2153<\/td><td>3 tacki<br>1 szt. PDU 10 A<br>4 wentylatory<\/td><\/tr><tr><td>1000<\/td><td>670*1070*2085<\/td><td>1.4947<\/td><td>3 tacki<br>1 szt. PDU 10 A<br>4 wentylatory<\/td><\/tr><tr><td>1200<\/td><td>670*1270*2085<\/td><td>1.7741<\/td><td>3 tacki<br>1 szt. PDU 10 A<br>4 wentylatory<\/td><\/tr><tr><td rowspan=\"4\">800<\/td><td>600<\/td><td>870*670*2085<\/td><td>1.2513<\/td><td>3 tacki<br>1 szt. PDU 10 A<br>2 wentylatory<\/td><\/tr><tr><td>800<\/td><td>870*870*2085<\/td><td>1.5781<\/td><td>3 tacki<br>1 szt. PDU 10 A<br>4 wentylatory<\/td><\/tr><tr><td>1000<\/td><td>870*1070*2085<\/td><td>1.9409<\/td><td>3 tacki<br>1 szt. PDU 10 A<br>4 wentylatory<\/td><\/tr><tr><td>1200<\/td><td>870*1270*2085<\/td><td>2.3037<\/td><td>3 tacki<br>1 szt. PDU 10 A<br>4 wentylatory<\/td><\/tr><tr><td rowspan=\"4\">47<\/td><td rowspan=\"4\">600<\/td><td>600<\/td><td rowspan=\"4\">2277<\/td><td>670*670*2307<\/td><td>1.0356<\/td><td>3 tacki<br>1 szt. PDU 10 A<br>2 wentylatory<\/td><\/tr><tr><td>800<\/td><td>670*870*2307<\/td><td>1.3448<\/td><td>3 tacki<br>1 szt. PDU 10 A<br>4 wentylatory<\/td><\/tr><tr><td>1000<\/td><td>670*1070*2307<\/td><td>1.6539<\/td><td>3 tacki<br>1 szt. PDU 10 A<br>4 wentylatory<\/td><\/tr><tr><td>1200<\/td><td>670*1270*2307<\/td><td>1.9630<\/td><td>3 tacki<br>1 szt. PDU 10 A<br>4 wentylatory<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Cz\u0119sto zadawane pytania<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Pytanie 1: Jaka jest g\u0142\u00f3wna cecha konstrukcyjna ramy szafki z serii F3?<\/strong> <\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A:<\/strong> Seria F3 wyposa\u017cona jest w przednie i tylne drzwiczki z sze\u015bciok\u0105tn\u0105 siatkow\u0105 p\u0142yt\u0105 wentylacyjn\u0105 o du\u017cej g\u0119sto\u015bci, zaprojektowane z my\u015bl\u0105 o optymalnym przep\u0142ywie powietrza i wydajno\u015bci ch\u0142odzenia pasywnego w \u015brodowiskach serwerowych o du\u017cej g\u0119sto\u015bci.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Pytanie 2: Jakie bran\u017cowe normy zgodno\u015bci maj\u0105 zastosowanie do serii F3?<\/strong> <\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A:<\/strong> Urz\u0105dzenie jest zgodne z normami ANSI\/EIA RS-310-D, IEC 297-2, DIN 41494 (cz\u0119\u015b\u0107 1 i cz\u0119\u015b\u0107 7) oraz ETSI.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Pytanie 3: Jakie s\u0105 parametry konstrukcyjne, no\u015bno\u015b\u0107 i stopie\u0144 ochrony IP?<\/strong> <\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A:<\/strong> Wykonane ze stali walcowanej na zimno SPCC (profil monta\u017cowy: 2,0 mm, k\u0105townik monta\u017cowy: 1,5 mm, pozosta\u0142e elementy: 1,2 mm) z wyko\u0144czeniem obejmuj\u0105cym odt\u0142uszczenie, trawienie i malowanie proszkowe. Zapewnia stopie\u0144 ochrony IP20 i wytrzymuje obci\u0105\u017cenie statyczne do 800 kg.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Pytanie 4: Jakie rozmiary i kolory s\u0105 dost\u0119pne?<\/strong> <\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A:<\/strong> Pojemno\u015bci wynosz\u0105 od 18U do 47U (18U, 22U, 27U, 32U, 37U, 42U, 47U), przy szeroko\u015bciach 600 mm lub 800 mm oraz g\u0142\u0119boko\u015bciach od 600 mm do 1200 mm. Dost\u0119pne kolory to czarny (RAL9004) i szary (RAL7035).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Pytanie 5: Jakie akcesoria s\u0105 do\u0142\u0105czone do zestawu i w jaki spos\u00f3b wysy\u0142ana jest szafka?<\/strong> <\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A:<\/strong> W zale\u017cno\u015bci od g\u0142\u0119boko\u015bci i wysoko\u015bci modelu szafy s\u0105 wyposa\u017cone w p\u00f3\u0142ki na sprz\u0119t (1 lub 3 sztuki), modu\u0142 PDU 10 A oraz wentylatory ch\u0142odz\u0105ce (2 lub 4 sztuki). Szafa jest wyposa\u017cona w stopki do r\u00f3wnania poziomu oraz wytrzyma\u0142e k\u00f3\u0142ka, zdejmowane panele boczne, regulowane i zamykane przepusty kablowe, a tak\u017ce opcj\u0119 dostawy w p\u0142askim opakowaniu, kt\u00f3ra zmniejsza obj\u0119to\u015b\u0107 przesy\u0142ki o 1\/2 do 2\/3.<\/p>","protected":false},"excerpt":{"rendered":"<p>Opis: Rama szafy sieciowo-serwerowej serii F3 z przedni\u0105 i tyln\u0105 p\u0142yt\u0105 wentylacyjn\u0105 o strukturze sze\u015bciok\u0105tnej o du\u017cej g\u0119sto\u015bci Drzwi przednie i tylne Normy Cechy G\u0142\u00f3wny materia\u0142 Wyko\u0144czenie powierzchni Stopie\u0144 ochrony No\u015bno\u015b\u0107 Pojemno\u015b\u0107 (U) Szeroko\u015b\u0107(mm) G\u0142\u0119boko\u015b\u0107 (mm) Wysoko\u015b\u0107 (mm) Wymiary opakowania (szer. \u00d7 g\u0142. \u00d7 wys.) Pojemno\u015b\u0107 (CBM) 18 600 600 988 670 \u00d7670 \u00d7 1028 0,5992 1\u00d7 p\u00f3\u0142ka, 1\u00d7 PDU 10 A, 2\u00d7 wentylatory 800 670 \u00d7 870 \u00d7 1028 0,5992 1\u00d7 p\u00f3\u0142ka, 1\u00d7 \u2026 <a title=\"Rama szafy sieciowej i serwerowej serii F3\" class=\"read-more\" href=\"https:\/\/firstfibertech.com\/pl\/product\/f3-series-network-and-server-cabinet-frame\/\" aria-label=\"Dowiedz si\u0119 wi\u0119cej o F3 Series Network and Server Cabinet Frame\">Dowiedz si\u0119 wi\u0119cej<\/a><\/p>","protected":false},"featured_media":2524,"template":"","ff_product_cat":[29,86],"class_list":["post-2523","ff_products","type-ff_products","status-publish","has-post-thumbnail","hentry","ff_product_cat-fiber-cable-management","ff_product_cat-server-network-frame"],"_links":{"self":[{"href":"https:\/\/firstfibertech.com\/pl\/wp-json\/wp\/v2\/ff_products\/2523","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/firstfibertech.com\/pl\/wp-json\/wp\/v2\/ff_products"}],"about":[{"href":"https:\/\/firstfibertech.com\/pl\/wp-json\/wp\/v2\/types\/ff_products"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/firstfibertech.com\/pl\/wp-json\/wp\/v2\/media\/2524"}],"wp:attachment":[{"href":"https:\/\/firstfibertech.com\/pl\/wp-json\/wp\/v2\/media?parent=2523"}],"wp:term":[{"taxonomy":"ff_product_cat","embeddable":true,"href":"https:\/\/firstfibertech.com\/pl\/wp-json\/wp\/v2\/ff_product_cat?post=2523"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}