{"id":842,"date":"2026-07-31T08:46:41","date_gmt":"2026-07-31T08:46:41","guid":{"rendered":"https:\/\/firstfibertech.com\/?post_type=ff_products&#038;p=842"},"modified":"2026-09-08T07:01:00","modified_gmt":"2026-09-08T07:01:00","slug":"identyfikator-swiatlowodu-ff-3306g-z-vfl-i-opm","status":"publish","type":"ff_products","link":"https:\/\/firstfibertech.com\/pl\/product\/ff-3306g-optical-fiber-identifier-with-vfl-and-opm\/","title":{"rendered":"Identyfikator \u015bwiat\u0142owodowy FF-3306G z VFL i OPM"},"content":{"rendered":"<h2 class=\"wp-block-heading\">Opis<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Identyfikator \u015bwiat\u0142owodu FF-3306G s\u0142u\u017cy do wykrywania kierunku sygna\u0142u i przybli\u017conej mocy w dowolnym po\u0142o\u017ceniu \u0142\u0105cza \u015bwiat\u0142owodowego SM i MM.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Podczas prac konserwacyjnych, instalacyjnych i okablowania cz\u0119sto zachodzi konieczno\u015b\u0107 odnalezienia lub zidentyfikowania konkretnego w\u0142\u00f3kna \u015bwiat\u0142owodowego bez przerywania sygna\u0142\u00f3w roboczych w w\u0142\u00f3knie.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Identyfikator FF-3306G s\u0142u\u017cy do identyfikacji sygna\u0142\u00f3w modulacyjnych (270 Hz\/1 kHz\/2 kHz) wstrzykiwanych do w\u0142\u00f3kna \u015bwiat\u0142owodowego na jednym ko\u0144cu.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Kierunek i intensywno\u015b\u0107<\/strong>&nbsp;S\u0142aby sygna\u0142 optyczny jest wykrywany po zgi\u0119ciu w\u0142\u00f3kna \u015bwiat\u0142owodowego, a kierunek i nat\u0119\u017cenie sygna\u0142u optycznego s\u0105 wykrywane poprzez ocen\u0119 kierunku i nat\u0119\u017cenia wycieku. Urz\u0105dzenie mo\u017ce bezpo\u015brednio wykrywa\u0107 w\u0142\u00f3kna \u015bwiat\u0142owodowe o \u015brednicy 0,25 mm oraz wewn\u0119trzne kable \u015bwiat\u0142owodowe o \u015brednicy 0,9 mm, 2,0 mm i 3,0 mm bez ich uszkadzania ani przerywania ci\u0105g\u0142ej komunikacji.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>VFL<\/strong>&nbsp;\u0179r\u00f3d\u0142o \u015bwiat\u0142a czerwonego ma moc 2mW i s\u0142u\u017cy do znajdowania punkt\u00f3w uszkodze\u0144 \u0142\u0105cza 5km.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>OPM<\/strong>&nbsp;z 8 skalibrowanymi d\u0142ugo\u015bciami fal, stosowany do pomiaru testowanego w\u0142\u00f3kna.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Monitorowanie niskiego poziomu baterii:<\/strong>&nbsp;gdy bateria jest s\u0142aba, zostanie wys\u0142any \u017c\u00f3\u0142ty lub czerwony komunikat przypominaj\u0105cy u\u017cytkownikowi o konieczno\u015bci wymiany baterii w celu unikni\u0119cia przerwy w u\u017cytkowaniu.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Cechy<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u2013 Kierunek i cz\u0119stotliwo\u015b\u0107 \u015bwiat\u0142a mo\u017cna okre\u015bli\u0107 bez przecinania w\u0142\u00f3kna \u015bwiat\u0142owodowego.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u2013 Zastosowano tryb pracy \u201cnaci\u015bnij, aby sprawdzi\u0107\u201d, aby obs\u0142uga by\u0142a prosta i wygodna.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u2013 Nie ma potrzeby wymiany adaptera w przypadku kabli \u015bwiat\u0142owodowych.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u2013 Potrafi rozpozna\u0107 trzy powszechnie stosowane cz\u0119stotliwo\u015bci sygna\u0142u: 2 kHz\/1 kHz\/270 Hz.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u2013 Mo\u017cna wy\u015bwietli\u0107 przybli\u017con\u0105 warto\u015b\u0107 mocy optycznej mierzonego w\u0142\u00f3kna \u015bwiat\u0142owodowego.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Specyfikacja<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td colspan=\"2\">Identyfikator \u015bwiat\u0142owodu<\/td><\/tr><tr><td>Zidentyfikowany zakres WL<\/td><td>800-1700nm<\/td><\/tr><tr><td>Zidentyfikowany typ sygna\u0142u<\/td><td>CW\/270Hz\/1kH\/2kHz<\/td><\/tr><tr><td>Typ detektora<\/td><td>InGaAs<\/td><\/tr><tr><td>Typ adaptera<\/td><td>Uniwersalny adapter do kabli wewn\u0119trznych 250um, 900um, 2mm, 3mm<\/td><\/tr><tr><td>Kierunek sygna\u0142u<\/td><td>Lewa i prawa dioda LED<\/td><\/tr><tr><td>Zakres testowy (kierunek)<\/td><td>-48 ~ +10dBm<\/td><\/tr><tr><td>Zakres testowy (moc)<\/td><td>-50 ~ +10dBm<\/td><\/tr><tr><td>Zakres testu cz\u0119stotliwo\u015bci<\/td><td>-25 ~ +10 dBm przy kablach 0,9 mm, 2,0 mm, 3,0 mm -10 ~ +10 dBm przy kablu 0,25 mm<\/td><\/tr><tr><td>Straty wtr\u0105ceniowe (typowe)<\/td><td>0,8 dB (1310 nm), 2,5 dB (1550 nm)<\/td><\/tr><tr><td colspan=\"2\">Lokalizator usterek wizualnych<\/td><\/tr><tr><td>Moc wyj\u015bciowa<\/td><td>2mW<\/td><\/tr><tr><td>D\u0142ugo\u015b\u0107 fali<\/td><td>650 nm<\/td><\/tr><tr><td>Z\u0142\u0105cze<\/td><td>Z\u0142\u0105cze uniwersalne 2,5 mm<\/td><\/tr><tr><td>Cz\u0119stotliwo\u015b\u0107<\/td><td>CW\/1Hz\/2Hz<\/td><\/tr><tr><td colspan=\"2\">Miernik mocy optycznej<\/td><\/tr><tr><td>Zakres d\u0142ugo\u015bci fali<\/td><td>800~1700nm<\/td><\/tr><tr><td>Z\u0142\u0105cze<\/td><td>Z\u0142\u0105cze uniwersalne 2,5 mm<\/td><\/tr><tr><td>Typ detektora<\/td><td>InGaAs<\/td><\/tr><tr><td>Zakres pomiaru<\/td><td>-70~+6dBm lub -50~+26dBm<\/td><\/tr><tr><td>Niepewno\u015b\u0107<\/td><td>\u00b15%<\/td><\/tr><tr><td>Skalibrowana d\u0142ugo\u015b\u0107 fali<\/td><td>850\/980\/1300\/1310\/1490\/1550\/1625\/1650nm<\/td><\/tr><tr><td>Rozdzielczo\u015b\u0107 wy\u015bwietlacza<\/td><td>0,01 dBm<\/td><\/tr><tr><td colspan=\"2\">Inni<\/td><\/tr><tr><td>Zasilacz<\/td><td>2 baterie AA<\/td><\/tr><tr><td>Temperatura pracy<\/td><td>-10 \u00b0C do +50 \u00b0C<\/td><\/tr><tr><td>Temperatura przechowywania<\/td><td>-40\u00b0C do +70\u00b0C<\/td><\/tr><tr><td>Wymiar<\/td><td>195x30x27mm<\/td><\/tr><tr><td>Waga<\/td><td>200g<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Do pobrania<\/h2>\n\n\n\n<div class=\"wp-block-group is-nowrap is-layout-flex wp-container-core-group-is-layout-8f761849 wp-block-group-is-layout-flex\"><div class=\"wp-block-icon\"><svg aria-hidden=\"true\" focusable=\"false\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 24 24\">\n\t<path d=\"M18 11.3l-1-1.1-4 4V3h-1.5v11.3L7 10.2l-1 1.1 6.2 5.8 5.8-5.8zm.5 3.7v3.5h-13V15H4v5h16v-5h-1.5z\" \/>\n<\/svg>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/firstfibertech.com\/wp-content\/uploads\/2026\/07\/FF-3306-G-Optical-Fiber-Identifier-Datasheet.pdf\">Karta katalogowa identyfikatora \u015bwiat\u0142owodu FF-3306G<\/a><\/p>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Cz\u0119sto zadawane pytania<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Pytanie 1: Jakie s\u0105 g\u0142\u00f3wne funkcje identyfikatora \u015bwiat\u0142owod\u00f3w FF-3306G?<\/strong> <\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A:<\/strong> Urz\u0105dzenie FF-3306G wykrywa kierunek sygna\u0142u oraz przybli\u017con\u0105 moc optyczn\u0105 w \u0142\u0105czach \u015bwiat\u0142owodowych jednomodowych i wielomodowych bez przerywania bie\u017c\u0105cej komunikacji. Urz\u0105dzenie rozpoznaje sygna\u0142y modulowane (270 Hz, 1 kHz, 2 kHz) i dzia\u0142a bezpo\u015brednio na go\u0142ym w\u0142\u00f3knie o \u015brednicy 0,25 mm, a tak\u017ce na kablach wewn\u0119trznych o \u015brednicach 0,9 mm, 2,0 mm i 3,0 mm przy u\u017cyciu uniwersalnego adaptera.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Pytanie 2: Jakie s\u0105 parametry techniczne wbudowanego lokalizatora uszkodze\u0144 optycznych (VFL)?<\/strong> <\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A:<\/strong> Wbudowany VFL dzia\u0142a przy d\u0142ugo\u015bci fali 650 nm, ma moc wyj\u015bciow\u0105 2 mW i jest wyposa\u017cony w uniwersalne z\u0142\u0105cze 2,5 mm, co pozwala na lokalizacj\u0119 uszkodze\u0144 na odcinku do 5 km wzd\u0142u\u017c \u0142\u0105cza \u015bwiat\u0142owodowego.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Pytanie 3: Jakie s\u0105 najwa\u017cniejsze cechy wbudowanego miernika mocy optycznej (OPM)?<\/strong> <\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A:<\/strong> Wbudowany modu\u0142 OPM jest wyposa\u017cony w detektor InGaAs o zakresie 800\u20131700 nm z 8 skalibrowanymi d\u0142ugo\u015bciami fal (850, 980, 1300, 1310, 1490, 1550, 1625 i 1650 nm). Urz\u0105dzenie zapewnia rozdzielczo\u015b\u0107 wy\u015bwietlacza wynosz\u0105c\u0105 0,01 dBm oraz oferuje zakresy pomiarowe od -70 do +6 dBm lub od -50 do +26 dBm.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Pytanie 4: Jakie s\u0105 wymiary fizyczne, \u017ar\u00f3d\u0142o zasilania i parametry \u015brodowiskowe?<\/strong> <\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A:<\/strong> Urz\u0105dzenie ma wymiary 195 \u00d7 30 \u00d7 27 mm, wa\u017cy 200 g i jest zasilane dwiema bateriami typu AA, wyposa\u017conymi w funkcj\u0119 ostrzegania o niskim poziomie na\u0142adowania. Dzia\u0142a w temperaturach od -10\u00b0C do +50\u00b0C.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Pytanie 5: Czym jest cena referencyjna i jak mog\u0119 z\u0142o\u017cy\u0107 zapytanie?<\/strong> <\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A:<\/strong> Cen\u0105 referencyjn\u0105 dla modelu FF-3306G jest $90. Mo\u017cna z\u0142o\u017cy\u0107 zapytanie, wybieraj\u0105c opcj\u0119 <strong>Dodaj do wyceny<\/strong> lub <strong>Popro\u015b o demo<\/strong> bezpo\u015brednio na stronie produktu.<\/p>","protected":false},"excerpt":{"rendered":"<p>Description The FF-3306G Optical fiber identifier is used to detect signal direction and approximate power at any position of SM and MM fiber link. During the maintenance, installation and cabling, it is often necessary to find or identify a specific optical fiber without interrupting the working signals in fiber. FF-3306G identifier is used to identify &#8230; <a title=\"Identyfikator \u015bwiat\u0142owodowy FF-3306G z VFL i OPM\" class=\"read-more\" href=\"https:\/\/firstfibertech.com\/pl\/product\/ff-3306g-optical-fiber-identifier-with-vfl-and-opm\/\" aria-label=\"Dowiedz si\u0119 wi\u0119cej o FF-3306G Optical Fiber Identifier with VFL and OPM\">Dowiedz si\u0119 wi\u0119cej<\/a><\/p>","protected":false},"featured_media":2634,"template":"","ff_product_cat":[21,11],"class_list":["post-842","ff_products","type-ff_products","status-publish","has-post-thumbnail","hentry","ff_product_cat-optical-fiber-identifier","ff_product_cat-test-and-measurement"],"_links":{"self":[{"href":"https:\/\/firstfibertech.com\/pl\/wp-json\/wp\/v2\/ff_products\/842","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/firstfibertech.com\/pl\/wp-json\/wp\/v2\/ff_products"}],"about":[{"href":"https:\/\/firstfibertech.com\/pl\/wp-json\/wp\/v2\/types\/ff_products"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/firstfibertech.com\/pl\/wp-json\/wp\/v2\/media\/2634"}],"wp:attachment":[{"href":"https:\/\/firstfibertech.com\/pl\/wp-json\/wp\/v2\/media?parent=842"}],"wp:term":[{"taxonomy":"ff_product_cat","embeddable":true,"href":"https:\/\/firstfibertech.com\/pl\/wp-json\/wp\/v2\/ff_product_cat?post=842"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}